AR-C170 (serv.man26). Simulation - Sharp Copying Equipment Service Manual (repair manual). Page 21

Read Sharp AR-C170 (serv.man26) Service Manual online

AR-C170M  SIMULATION  9 - 21
(Trouble codes to be canceled)
(Trouble codes to be canceled)
(Trouble codes to be canceled)
The maintenance message is displayed in every selected cycle. 
When FREE is selected, the maintenance display is not shown.
(Cycle to be set)
14
14
-0
Purpose
Clear/cancel (Trouble etc.)
Function 
(Purpose)
Used to cancel self diag troubles H3, H4, and H5. 
Inhibition of the color copy mode operation is 
canceled.
Item
Trouble
Error
Operation/
Procedure
1. Press the [EXECUTE] key. (YES/NO key 
display)
2. When YES key is pressed, the following troubles 
are cleared. (Cancel with NO key.)
Target trouble 
codes
Descriptions
H3-00
Heat roller high temperature detection (HL1)
H3-01
Heat roller high temperature detection (HL2)
H4-00
Heat roller low temperature detection (HL1)
H4-01
Heat roller low temperature detection (HL2)
H5-01
Five continuous detections of POD1 not-
reached jam
15
15
-0
Purpose
Clear/cancel (Trouble etc.)
Function 
(Purpose)
Self diag U6-09 (large capacity paper feed tray) 
trouble cancel
Section
Paper feed
Item
Trouble
Error
Operation/
Procedure
Press the [EXECUTE] key to cancel the trouble.
Press the [CLOSE] key to terminate the 
simulation.
16
16
-0
Purpose
Clear/cancel (Trouble etc.)
Function 
(Purpose)
Used to cancel self diag trouble U2.
Item
Trouble
Error
Operation/
Procedure
1. Press the [EXECUTE] key. (YES/NO key display)
2. When YES key is pressed, the following troubles 
are cleared. (Cancel with NO key.)
Target trouble codes
Descriptions
U2-00
EEPROM read/write error (OPE)
U2-11
EEPROM check sum error (OPE)
U2-80
EEPROM read/write error (SCN)
U2-81
EEPROM check sum error (SCN)
U2-90
EEPROM read/write error (PCU)
U2-91
EEPROM check sum error (PCU)
17
17
-0
Purpose
Clear/cancel (Trouble etc.)
Function 
(Purpose)
Used to cancel self diag troubles PF (copy inhibition 
command from the host computer).
Section
Communication (RIC/MODEM)
Item
Trouble
Error
Operation/
Procedure
1. Press the [EXECUTE] key. (YES/NO key 
display)
2. When YES key is pressed, the following troubles 
are cleared. (Cancel with NO key.)
Target trouble codes
Descriptions
PF-00
PC copy inhibition signal reception
21
21
-1
Purpose
Setting
Function 
(Purpose)
Used to set the maintenance cycle.
Item
Specifications
Counter
Operation/
Procedure
1. The current setup is displayed. (Highlighted)
2. When the maintenance cycle is selected with the 
key, the selected key is highlighted.
Item
Set value
Content
Default
CYCLE
0
5K
50K
1
10K
2
15K
3
40K
4
50K
5
100K
6
FREE