AR-651/810 FUSER UNIT 14 - 17
[E] Upper separation finger unit
(1) Remove 2 screws and take off the crank plate
and upper separation finger unit.
(2) Remove each spring and take off each
separation finger.
[F] Cleaning roller (metal)/Lower separation finger
(1) Remove 2 screws and open the guide.
(2) Remove the cleaning roller (metal).
(3) Remove each spring and take off each lower
separation finger.
Crank plate
Upper separation finger unit
Spring
Upper separation finger
Cleaning roller (metal)
Spring
Lower separation finger