AR-651 (serv.man17). Fuser unit - Sharp Copying Equipment Service Manual (repair manual). Page 14

Read Sharp AR-651 (serv.man17) Service Manual online

AR-651/810  FUSER UNIT  14 - 14
[B]  Fuser unit
(1) Remove 2 screws and open the cover forward
slowly.
(2) Remove 4 screws and release the IH coil fuser
harness. Disconnect 2 connectors.
(3) Remove 1 screw and open the cover 2 forward.
(4) Remove 1 screw move the fuser unit forward
and lift it off upward.
Notes: 1. Make sure that the harness (A) at the right
figure does not touch the bearing and shaft
of the transfer/transport unit when installing
the fuser unit.
2. Remove the fuser unit after fully lowering
the temperature or wear gloves and such
when removing it at a high temperature.
3. Hold B sections of the fuser unit when
installing/removing it.
[C]  Cleaning web unit
(1) Remove 2 black screws and take off the cleaning
web unit.
Note: The cleaning web unit can be taken off without
removing the fuser unit.
(2) Remove 4 E-rings and take off the cleaning web.
(3) Remove 2 E-rings and take off the bushing and
gear.
Caution: Be careful not to create slack in the cleaning
web when installing it.
C
G
S
C
S
Connector
E-ring
E-ring
Cleaning web
E-ring
A
B
Cover 2
Page of 21
Display

Click on the first or last page to see other AR-651 (serv.man17) service manuals if exist.