AR-651 (serv.man17). Fuser unit - Sharp Copying Equipment Service Manual (repair manual). Page 15

Read Sharp AR-651 (serv.man17) Service Manual online

AR-651/810  FUSER UNIT  14 - 15
(4) Remove 2 E-rings and take off the web pushing
roller.
Cautions:
1.
Take up the cleaning web a little (3~5 rotations with
hand) after replacing the cleaning web and web
pushing roller.
2.
When installing the cleaning web unit to the fuser
unit, make sure that the web is not slacked off.
3.
Turn the fuser unit jam access knob 10~15 times to
adapt the cleaning web to the fuser roller. At this
time make sure that there is no defect caused by an
installing inadequacy.
4.
Make sure that the cleaning web is not 
wrinkled
or slacked off.
5.
Set up the PM support mode “6S” and clear the
cleaning web counter. After clearing it, the web
motor automatically rotates for 65 seconds when
turning the power ON.
6.
Turn the power ON and make sure that “READY” is
displayed.
7.
Finally confirm the fuser unit is in a proper condition.
8.
Do not rotate the web motor for more than 2 min. at
the output check (03-124) since the cleaning web
may be slacked off when rolled up.
Note: Approximate remaining web can be seen through
the window at the fuser unit (shown by the right
figure).
Low
Full
E-ring
Pin
Page of 21
Display

Click on the first or last page to see other AR-651 (serv.man17) service manuals if exist.