AR-651 (serv.man17). Fuser unit - Sharp Copying Equipment Service Manual (repair manual). Page 16

Read Sharp AR-651 (serv.man17) Service Manual online

AR-651/810  FUSER UNIT  14 - 16
[D] IH coil
(1) Remove the cleaning web unit.
(2) Remove 2 screws and take off the fuser cover
(front).
(3) Remove 2 screws and take off the bracket.
(4) Pull out the IH coil.
Note: Make sure that the “C” and “S” harnesses of the
power supply harness comes to the left side when
installing the IH coil.
S
C
Page of 21