AR-651 (serv.man17). Fuser unit - Sharp Copying Equipment Service Manual (repair manual). Page 10

Read Sharp AR-651 (serv.man17) Service Manual online

AR-651/810  FUSER UNIT  14 - 10
14. 4. 6.  Detection of open-circuited thermistors
A thermistor is a device which resistance decreases when it detects a high temperature. If the fuser roller
thermistor is open-circuited, the control circuit finds that the fuser roller temperature is extremely low and
keeps turning ON the IH coil. As a result, the fuser roller temperature rises, possibly activating the thermostat,
which is a safety protection device. To prevent this, CPU works to detect if the thermistor is open-circuited
or not.
* The following is a circuit diagram of the thermistor open-circuit detection circuit common with the center
and side thermistors.
· The input voltage is obtained by dividing the resistor
1, thermistor, resistor 2 and resistor 3.
· The temperature of the fuser roller surface changes.
The resistance of the thermistor changes.
The input voltage changes.
· The main CPU detects this change of the input
voltage to decide if the thermistor is abnormal or not.
Thermistor
Main CPU
R1
+5
R2
R3
C
 R4