4.Action:
Higher harmonics transistor:
From the start of 1997 February production.
Discontinued of screw:
From the start of 1997 February production.
Pinched electrical line action:
(Temporary action):
From machine no. 210 of 1997 February
production.
(Permanent action):
From the start of 1997 March production.
Discontinued of the main SW harness protector sheet:
From the start of 1997 May production.
Ref.
No.
Model
name
Version
P/G No.
Current parts
New parts
Parts name
Effec-
tive
time
Inter-
change-
ability
Note
Parts code
Parts code
Price 
rank
AR-5132
Overseas
10    -63
RCILF0079FCZZ
RCILF0079FCZ1
AZ
Higher harmonics transistor
1st lot
‘97/2
6
200V
10    -1
XHBSE40P10000
M4
10 bind
S tight
1 discontinued
(of 3)
Overseas
7
-33
PSHEP4437FCZZ
Main SW  hernes Protector
sheet
1st lot
‘97/5
PSHEP4490FCZZ
AF
Fan duct protector sheet
1st lot
‘97/3
<In ter change>
1. In ter change able.
4. Not in ter change able.
2. Cur rent type can be used in place of new type.
     New type can not be used in place of cur rent type.
5. In ter change able if re placed with same types of 
     re lated parts in use.
3. Cur rent type can not be used in place of new type.
     New type can be used in place of cur rent type.
6. Oth ers.
Parts marked with “      ” is im por tant for main tain ing the safety of the set. Be sure to re place these parts with
 
spec i fied ones for main tain ing the safety and per for mance of the set.
Sharp Electronics (UK) Ltd, Copier Technical Support, Technical Service Group