MEASURE TO PREVENT THE ELECTRICAL LINES FROM
BECOMING PINCHED BY THE FAN ATTACHMENT PLATE UNIT.
1.Model Name:
AR-5132
2.General:
There was a mistake found in the parts guide of the AR-5132 model. The part code for
the higher harmonics transistor was incorrect and has been corrected. Furthermore,
one of the fixing screws of the fusing drawer attachment UN has been discontinued,
and a protector sheet has been added to the fan duct to prevent the electrical lines from 
becoming pinched by the fan attachment UN. These changes have been carried out as
a measure to improve productivity. In accordance with the addition of the protector
sheet to the fan duct, the main SW harness protect sheet has been discontinued.
3.Description:
Location of the discontinued attachment screw of the fusing drawer.
Discontinued
Only the 200 VEX
is unnecessary.
Fusing drawer
attachment plate
Position of the 100 V series
EX power supply grounding
screw retainer.
Rear frame
Date :
Model :    
Ref :
Colour Code :
Pages :  1  of 
30 April 1998
AR-5132
AR5132-005
  White
 
3
COPIER
TECHNICAL BULLETIN
Sharp Electronics (UK) Ltd, Copier Technical Support, Technical Service Group
Originators Initials_____________ Supervisors Initials_____________ Approval Date: 30th April 1998  (ARE026)
Added fan duct protector sheet
(1)Temporary action
The addition of wrapped tape to the main SW harness has been carried out.
(2)Permanent action
The addition of a fan duct protector sheet has been carried out in the fan duct 
attachment section.
1) The fan duct protector sheet should be attached with the sheet corner aligned to
the X-Y standard on the right side.
The fan protector sheet on the front side should be attached with the slit of the
sheet aligned to the X’-Y’ standard. (Please refer to figure 2.)
2) The main SW harness should be wrapped with the fan duct protector sheet and 
attached. (Please refer to figure 3.)
Main SW harness:
DHAI-2773FCZZ
Figure 1
Fan duct
Vinyl tape is wrapped once to the harness
which is laid out in a flat position.
(Note: This action should be carried out 
on both the front and rear sides.)
Paper delivery side
Rear side
Standard Y
Rear side
Standard X
Standard X (Align with the
ear of the metal plate.)
Double
sided tape
Standard X’
Standard Y’
Paper delivery side
Fan duct protector
sheet
Front side
Figure 2
Fan duct protector sheet
Main SW harness:
DHAI-2773FCZZ
Figure 3
    Sharp Electronics (UK) Ltd, Copier Technical Support, Technical Service Group
Model:AR5132                                                                 Bulletin number: AR5132-005                                  Page: 2 of 3
4.Action:
Higher harmonics transistor:
From the start of 1997 February production.
Discontinued of screw:
From the start of 1997 February production.
Pinched electrical line action:
(Temporary action):
From machine no. 210 of 1997 February
production.
(Permanent action):
From the start of 1997 March production.
Discontinued of the main SW harness protector sheet:
From the start of 1997 May production.
Ref.
No.
Model
name
Version
P/G No.
Current parts
New parts
Parts name
Effec-
tive
time
Inter-
change-
ability
Note
Parts code
Parts code
Price 
rank
AR-5132
Overseas
10    -63
RCILF0079FCZZ
RCILF0079FCZ1
AZ
Higher harmonics transistor
1st lot
‘97/2
6
200V
10    -1
XHBSE40P10000
M4
10 bind
S tight
1 discontinued
(of 3)
Overseas
7
-33
PSHEP4437FCZZ
Main SW  hernes Protector
sheet
1st lot
‘97/5
PSHEP4490FCZZ
AF
Fan duct protector sheet
1st lot
‘97/3
<In ter change>
1. In ter change able.
4. Not in ter change able.
2. Cur rent type can be used in place of new type.
     New type can not be used in place of cur rent type.
5. In ter change able if re placed with same types of 
     re lated parts in use.
3. Cur rent type can not be used in place of new type.
     New type can be used in place of cur rent type.
6. Oth ers.
Parts marked with “      ” is im por tant for main tain ing the safety of the set. Be sure to re place these parts with
 
spec i fied ones for main tain ing the safety and per for mance of the set.
Sharp Electronics (UK) Ltd, Copier Technical Support, Technical Service Group
Model:  AR-5132                                                              Bulletin number: AR5132-005                                  Page: 3 of 3
Page of 3
Display

Download Sharp AR-5132 (serv.man131) Technical Bulletin

Here you can read online and download Sharp AR-5132 (serv.man131) Technical Bulletin in PDF. AR-5132 (serv.man131) technical bulletin will guide through the process and help you recover, restore, fix, disassemble and repair Sharp AR-5132 (serv.man131) Copying Equipment. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.