AR-505 (serv.man9). AR505 Service Manual-Simulation - Sharp Copying Equipment Service Manual (repair manual). Page 39

Read Sharp AR-505 (serv.man9) Service Manual online

46 - 20
Purpose
Adjustment
Function
(Purpose)
Used to adjust the copy density correction in the SPF
copy mode for the document table copy mode.  Adjust-
ment is made so that the copy density is the same as
that in the document table copy mode. (Target models:
AR-2X1/3X1/4XX/250/XX6/5XX series)
Item
Picture quality
Density
Operation/
Procedure
1. Select the print mode with [
] key or [
] key.
(The display of the set value is highlighted.)
2. Enter the adjustment value with the 10-key.
3. Press the [OK] key or the [PRINT] key.
(The value entered in procedure 2 is set.)
A: OC/SPF exposure correction value
Set range: 0 ~ 100
Center value: 50
(Default: 60)
(AR-501/505)
(Other models)
48
48 - 1
Purpose
Adjustment
Function
(Purpose)
Used to adjust the copy magnification ratio (main scan-
ning direction, sub scanning direction).
Section
ICU
Item
Picture quality
Operation/
Procedure
1. Select the adjustment mode with [
], [
] keys.
2. Enter the adjustment value with the 10-key.
3. Press the [OK] key.
The value entered in procedure 2 is set.
a. Sub scan direction magnification ratio --- (SCAN)
The horizontal print magnification ratio (in the paper
transport direction) of the image is adjusted by changing
the scan speed in the paper transport direction.
b. Main scan direction magnification ratio --- (F-R)
The vertical print magnification ratio (front frame to near
frame) is adjusted in the image process section by the
software operation.
c. Sub scan direction magnification ratio adjustment value
(When SPF is used) --- (SPF)
(When RSPF is used) --- (RSPF (SIDE1))
The horizontal print magnification ratio (in the paper
transport direction) is adjusted by changing the document
transport speed.
d. Sub scan direction magnification ratio adjustment value
(When RSPF is used) --- (RSPF (SIDE2))
The horizontal print magnification ratio (in the paper
transport direction) is adjusted by changing the document
transport speed.
(When the set value is changed by 1, the magnification
ratio is changed by about 0.1%.)
Default: 50
(AR-501/505)
(Other models)
50
50 - 1
Purpose
Adjustment
Function
(Purpose)
Used to adjust the copy image position and the void
area (image loss) on the print paper in the copy mode.
(The same adjustment can be made with SIM 50-2
(simple method).)
Item
Picture quality
Image position
Operation/
Procedure
1. Select the adjustment item with [
] [
] keys.
2. Enter the adjustment value with the 10-key.
3. Press the [OK] key. (The adjustment value entered in proce-
dure 2 is set.)
(RRC-A)
This set value is used to align the document image lead edge
ad the scan image data lead edge in the document table scan
mode.
After starting scanning, the image lead edge position is deter-
mined by using the scanner home position detection signal
(MHPS) OFF timing as the reference.
RRC-A set value = Time (distance) from the output of the
scanner home position detection signal (MHPS OFF) to the im-
age lead edge position.
If this setting is not made properly, the image lead edge posi-
tion (image loss) varies depending on the copy magnification
ratio.
When the set value is increased, the image position is shifted
in the advancing direction on the paper.
When the set value is changed by 1, the image lead edge posi-
tion is varied.
(SPF)
This set value is used to align the document image lead edge
position and the scan image data lead edge position in the
SPF scan mode.
After starting scanning, the scan image lead edge position is
determined by using the resist sensor detection signal (REGS
ON) timing as the reference.
RRC-A set value = Time (distance) from the output (resist sen-
sor detection signal (REGS ON) to the image lead edge posi-
tion.
AR-505
10/8/1999
7 – 38
Page of 51
Display

Click on the first or last page to see other AR-505 (serv.man9) service manuals if exist.