AR-505 (serv.man9). AR505 Service Manual-Simulation - Sharp Copying Equipment Service Manual (repair manual). Page 41

Read Sharp AR-505 (serv.man9) Service Manual online

b. Distance from the paper lead edge to the image lead edge 
L2
c. Distance from the image lead edge to the scale of 10mm (SPF
mode 200%) 
 L3
The measurement value is multiplied with 10 to enter.
With the above procedure, the values of RRC-A and RRC-B in
SIM 50-1 are automatically calculated and set.By directly setting
the values (actual dimensions [mm] x 10) of IMAGE LOSS, DEN-A
and DEN-B, the lead edge image loss, the lead edge void area,
and the rear edge void area can be set.
By setting the image loss, DEN-A, DEN-B (actual dimension (mm)
x 10) and REAR LOSS (SPF) (actual dimension (mm)) directly,
the lead edge image loss, the lead edge void area, the rear edge
void area and the rear edge image loss (SPF) can be set.
Code
Adjustment item
Adjustment
value
Note
A
L1
Distance
between the
image lead
edge and the
scale of 10mm.
When the image
lead edge
position varied
depending on
the copy
magnification
ratio, change
the set value.
B
L2
Distance
between the
paper lead edge
and the image
lead edge.
C
L3
Distance
between the
image lead
edge and the
scale of 10mm
(SPF mode).
When the image
lead edge
position varied
depending on
the copy
magnification
ratio, change
the set value.
D
IMAGE
LOSS
Lead edge
image loss
1.5 to
3.0mm
The greater the
set value is, the
greater the
image loss is.
E
DEN-A
Lead edge void
area
1.5 to
3.0mm
The greater the
set value is, the
greater the void
area is.
F
DEN-B
Rear edge void
area
1.5 to
3.0mm
The greater the
set value is, the
greater the void
area is.
G
REAR
LOSS
(SPF)
Rear edge
image loss (SPF
mode)
The greater the
set value is, the
greater the
image loss is.
(AR-2X1/3X1
/4XX/250/XX6
series only)
50 - 5
Purpose
Adjustment
Function
(Purpose)
Used to adjust the print image position (top margin) on
the print paper in the print mode.
Item
Picture quality
Print area
Operation/
Procedure
1. Enter the adjustment value with the 10-key.
2. Press the [EXECUTE] key to set the adjustment
value entered in procedure 1.
When the set value is increased, the top margin is increased.
When the set value is changed by 1, the top margin is changed
by about 0.1mm.
Default: 50
50 - 6
Purpose
Adjustment
Function
(Purpose)
Used to adjust the copy lead edge. (RSPF)
Item
Picture quality
Print area
Operation/
Procedure
1. Perform the 0C lead edge adjustment with SIM 60-
1/2. (To use the 0C lead edge void quantity.)
2. Set the image loss quantity (LOSS (RSPF)) to a desired value.
(0 - 99: 0.1 mm/step)
3. Adjust the original scanning start position (RSPF
(SIDE1)/RSPF (SIDE2)) so that the actual copy image loss
quantity is as specified in procedure 2. (0 - 99: 0.1 mm/step)
4. Adjust the rear edge void quantity (DEN-B). (0 - 99: 0.1
mm/step)
5. Adjust the rear edge image loss quantity (REAR LOSS (SPF))
when the SPF is used. (0 - 20 mm/step)
There are five input items of the copy lead edge adjustment;
LOSS (RSPF), RSPF (SIDE1), RSPF (SIDE 2), DEN-B, and
REAR LOSS (RSPF). Select the desired item with [
], [
] keys to
change the set value.
1. Image loss quantity setup value (RSPF ) --- (LOSS (RSPF))
Used to adjust the output timing of the image lead edge signal
(SCAN signal) after starting scanning of the original. (0 - 99:
Reference value 20)
2. Original front surface scanning start position adjustment value -
-- (RSPF (SIDE1))
Used to set the time from the start of original feed to reaching
at the exposure position. ([Front surface] (0 - 99: Reference
value 50)
3. Original back surface scanning start position adjustment value
--- (RSPF (SIDE2))
Used to set the time from the start of original feed to reaching
at the exposure position. [Back surface] (0 - 99: Reference
value 50)
AR-505
10/8/1999
7 – 40
Page of 51
Display