AR-505 (serv.man9). AR505 Service Manual-Simulation - Sharp Copying Equipment Service Manual (repair manual). Page 35

Read Sharp AR-505 (serv.man9) Service Manual online

LD_AD:
Laser power correction power display (mW)
AUTO:
Auto mode
CHARA:
Character mode
CHARA_P: Character/photo mode
PHOTO:
Photo mode
PRT:
Printer mode
FAX:
Fax mode (Japan only)
44 - 12
Purpose
Operation data output/Check (Display/Print)
Function
(Purpose)
Used to check the toner image patch density date in
correction operation of the image forming section. (This
simulation allows to check whether the correction is
executed properly or not. )
Section
Image process (Photoconductor/Developping/Transfer/
Cleaning)
Item
Data
Operation data
(Machine condition)
Operation/
Procedure
The latest developing bias correction data is displayed.
The sensor detection level (density) in the toner image
patch section/OPC drum base during the developing
bias corection is displayed.
DMLED:
Drum marking sensor gain adjustment level
PCLED:
Image density sensor gain adjustment level
DV_BS:
The developing bias voltage level when forming
PT2/BS2 of ID (1)
PT1/BS1:
No. 1 toner image patch section/Drum base sensor
detection level
PT2/BS2:
No. 2 toner image patch section/Drum base sensor
detection level
PT3/BS3:
No. 3 toner image patch section/Drum base sensor
detection level
ID (n) : Sequence number of correction operation
44 - 15
Purpose
Setting
Function
(Purpose)
Used to set the correction values of various parameters
(maincharger grid voltage, laser beam power, develop-
ing bias voltage) in the image forming operation and
image forming section correction for OPC drum type A.
(AR-250/280/281/285/286/335/336/405 only)
Section
Image process (Photoconductor/Developing/Transfer/
Cleaning)
Item
Operation
Operation/
Procedure
Used to set various parameters of image forming op-
eration and image forming section correction operation
for drum type A.
1. Select the correction item with [
­
], [
¯
] keys.
2. Enter the set value with the 10-key
3. Press the [OK] key. (The value entered in procedure 2 is set.)
DV BIAS:
Developing bias base voltage (Equivalent
to SIM 8-1 for Drum type B.) (500)
GIRD BIAS:
Main charger grid voltage (Equivalent to
SIM 8-2 for drum type B.) (475)
LD POWER:
Laser power (Equivalent to SIM 61-2 for
drum type B.) For
AR-2X1/3X1/4XX/250/XX6 series, set to
"10" (default). For AR-230/250/285/330/335
series, set to "16."
PROCON DB:
Base developing bias voltage in toner
image patch forming (in developing bias
correction) (Equivalent to SIM 44-5B) (500)
(Correction value to SIM 44-5B)
PROCON GB:
Base main charger grid voltage (Equivalent
to SIM 44-5A in drum type B) (500)
(Correction value to SIM 44-5A)
PROCON TARGET: Target image (reference) density level in
developing bias voltage correction
(Equivalent to SIM 44-4 4 in drum type B)
(58)
Be sure to set to the specified value.
Note
Be sure to set to the specified value. If not, the print im-
age density may be disturbed.
46
46 - 2
Purpose
Adjustment
Function
(Purpose)
Used to adjust the copy density in the copy mode (bi-
nary/multi-value  - auto, character and photo, photo
mode). 
(The overall print density in each mode (all of the speci-
fied density set for each density level (display value))
can be adjusted in each mode.)
Item
Picture quality
Density
Operation/
Procedure
1. Select the print mode with [
­
], [
¯
] keys.
(The set value is highlighted.)
2. Enter the adjustment value with the 10-key.
AR-505
8/6/1999
7 – 34
Page of 51