AR-505 (serv.man9). AR505 Service Manual-Simulation - Sharp Copying Equipment Service Manual (repair manual). Page 32

Read Sharp AR-505 (serv.man9) Service Manual online

41 - 2
Purpose
Adjustment
Function
(Purpose)
Used to adjsut the document size sensor detection
level.
Section
Others
Item
Operation
Operation/
Procedure
1. Open the original table, and press the [EXECUTE]
key with no original on the original table. The sensor
level setting with no original on the table is per-
formed. 
(Normal case) The COMPLETE display is highlighted (for 1
sec), then it returns to the normal display.
(Abnormal case) The INCOMPLETE display and the
abnormal sensor name are highlighted. 
2. Set an A3 paper (11" x 17") and press the [EXECUTE] key.
The sensor level setting with original is performed.
(Normal case) The COMPLETE display is highlighted (for 1
sec), then it returns to the normal display. The
"NO ORIGINAL" display turns to "A3
ORIGINAL".
(Abnormal case) The INCOMPLETE display and the
abnormal sensor names are highlighted.
41 - 3
Purpose
Operation test/check
Function
(Purpose)
Used to check the operation of the document size sen-
sor and the related circuit. (The document size sensor
output level can be monitored with the LCD.)
Section
Others
Item
Operation
Operation/
Procedure
The detection output level of each sensor is displayed
in real time.
OCSW
Document cover state
PD*
Document sensor
*
The value in [ ] shown at the right of each sensor name is the
threshold value.
43
43 - 1
Purpose
Setting
Function
(Purpose)
Used to set the fusing temperature in each operation
mode.
Section
Fixing (Fusing)
Item
Operation
Operation/
Procedure
1. Select the kind of lamps and the operation mode
with [
­
], [
¯
] keys.
2. Enter the set value with the 10-key.
3. Press the [OK] key to set the fusing temperature set in proce-
dure 2.
Used to set the fusing temperature in the normal mode and in
the power save mode.
INSIDE NORMAL:
The control temperature in the normal
mode and when the center lamp is
heated. (190) (AR-501/505 (200))
OUTSIDE NORMAL: The control temperature in the power
save mode (pre-heat mode) and the side
lamps are heated. (190) (AR-501/505
(200))
INSIDE PREHEAT:
The control temperature in the manual
copy mode when the center lamp is
heated. (*1)
OUTSIDE PREHEAT: The control temperature in the manual
copy mode when the side lamps are
heated. (*2)
INSIDE MFT:
The control temperature in the manual
copy mode when the center lamp is
heated. (200)
OUTSIDE MFT:
The control temperature in the manual
copy mode when the side lamps are
heated. (200)
( ): 
Default
Destination
Pre-heat mode fusing temperature set value
MODEL
AR-230/280/285 
series
AR-2X1/2X6/3X1
/250 series
AR-330/335
series
AR-3X6 series
AR-4XX series
AR-501/505
U.S.A. (Inch)
125
130
140
Canada (Inch)
125
130
140
Other (Inch)
125
130
140
Japan
130
130
140
Other (AB)
125
130
140
Europe (AB)
110
130
140
U.K. (AB)
110
130
140
Aus. (AB)
110
130
140
AR-505
7 – 31
8/6/1999
Page of 51
Display