AR-405. Cougar Handy Guide (Updated March'02) - Sharp Copying Equipment Handy Guide. Page 52

Read Sharp AR-405 Handy Guide online

 
IC-22  
 
SHARP ELECTRONICS (UK) LTD 
DOCUMENT SYSTEMS GROUP
 
52 
VERSION 1C 
MARCH 2002
 
 
 
11. 
Adjust all RADF sensors using Simulation 53-02. 
 
Once the above settings have all been input, check the following Test  
Simulation settings by comparing the Data Sheets:- 
 
 
Simulation 8-01 & 8-02 
DV & HV output settings. 
 
Simulation 26-35 
 
Error trouble count. 
 Simulation 
46  Exposure 
settings. 
 
Simulation 50 
 
Lead edge and void settings. 
 
Simulation 51 
 
Resist roller buckle. 
 
 
 
Cougar Total Counter Setting 
 
 
Re-enter the following machine meter readings from the engine data print:- 
 
    Total 
Counter  Simulation 
81 
    Maintenance 
Counter 
Simulation 
82 
    “Copies” 
Counter 
 Simulation 
83-06 
    “Printer” 
Counter 
 Simulation 
83-10 
    “Others” 
Counter 
 Simulation 
83-12 
“Scan” Counter 
 
Simulation 83-13 
Developer Counter   
Simulation 85 
 
 
Note: 
For Non Cougar 2000 models (eg AR335), the “Copy” counter reading that is  
obtained by the customer (by holding down the Copy button on the operation  
display) can only be re-entered in “Hex Value” by using Test Simulation 79.  
 
 
Example 1:- 
 
If the count is 1,500 , the Hex value of “5DC” is to be entered within the addresses 
0052 ~ 0055 as follows:– 
 
Input 00  
in address 0052 
Input 00  
in address 0053 
Input 05  
in address 0054 
Input DC 
in address 0055 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Cont’d 