AR-235 (serv.man93). Countermeasure against dropping of developer in the machine - Sharp Copying Equipment Technical Bulletin (repair manual). Page 3

Read Sharp AR-235 (serv.man93) Technical Bulletin online

DCE434
Sharp Electronics (UK) Ltd., Technical Services Group
3. Replace the TR electrode plate.
       - Disengage the old TR electrode plate from the positioning projection, and slide it in the
          direction of the arrow (A) to pull it out.
       - Insert the new TR electrode plate from the portion shown by the arrow (B), and mount it
          to the transfer unit in the reverse order from the disassembly.
4. Assemble
5. Action
Included from the production in October 2003.
Current parts
New parts
N
o
Model
name
Versio
n
P/G
No.
Parts code
Parts code
Price
rank
Q'ty
Parts
name
Effec-
tive
time
Inter-
change
-
ability
Note
17 -32
LPLTM0092QSZZ
LPLTM0363QSZZ
AF
2
Rail
reinforce
plate
3
17 -24
XHBSD30P10000
XHBSD30P10000
AA
4
Screw
(M3
××××
10)
-
Quantit
y
Change
2
!
!
!
!4
17 -18
MSPRC0248QSZ1
MSPRC0348QSZZ
High
voltage
Spring A
17 -17
MSPRC0249QSZ1
MSPRC0349QSZZ
High
voltage
Spring B
Rail
reinforce
plate
3
1
AR-235
AR-275
ALL
17 -
-
LPLTM0365QSZZ
AD
1
TR
electrode
plate
'03/10
-
<Interchange>
1. Interchangeable.
4. Not Interchangeable.
2. Current type can be used in place of new type.
New type cannot be used in place of current type.
5. Interchangeable if replaced with same types of related
parts in use.
3. Current type cannot be used in place of new type.
New type can be used in place of current type.
6. Others.
Parts marked with "
" is important for maintaining the safety of the set. Be sure to replace these parts with specified
ones for maintaining the safety and performance of the set.
Page of 3
Display

Download Sharp AR-235 (serv.man93) Technical Bulletin