(Identification of the old and new TR electrode plates)
[TR electrode plate replacement procedure]
1. Detach the reinforcement plate from the transfer unit. (3 screws. One of them is tightened
with the earth terminal.)
2. Remove the transfer roller ass'y.
Release the hooks on the front/rear frame side (2 pieces each at back and front) using a
slotted screwdriver, etc. to detach the transfer roller ass'y.