AR-235 (serv.man9). Adjustments, setting Simulation Trouble code list - Sharp Copying Equipment Service Manual (repair manual). Page 50

Read Sharp AR-235 (serv.man9) Service Manual online

AR-235/275 TROUBLE CODE LIST - 1
[9] TROUBLE CODE LIST
1. List
Trouble 
code
Trouble contents
Trouble 
detection
Main 
code
Sub 
code
E1
00
IMC board communication trouble
MCU
10
IMC board trouble
11
IMC ASIC error
12
IMC CODEC error
13
IMC board flash ROM error
14
IMC board Work RAM error
15
IMC board Page Memory error
16
IMC board image compression store 
memory error
17
IMC board smoothing IC error
80
IMC PWB communication trouble 
(protocol)
81
IMC PWB communication trouble (Parity)
82
IMC PWB communication trouble 
(Overrun)
84
IMC PWB communication trouble 
(Framing)
88
IMC PWB communication trouble (Time-
out)
E7
02
LSU trouble
10
Shading trouble (black correction)
11
Shading trouble (white correction)
12
Shading trouble
F1
00
Finisher communication trouble
FIN
01
Finisher jogger shift trouble
06
Finisher shift motor abnormality
08
Finisher staple shift motor trouble
11
Pusher motor trouble
15
Finisher elevator motor trouble
F2
02
Toner supply failure
04
Identification error
Model error
Type error
Destination error
Data abnormality
Misc error
F5
02
Copy lamp lighting abnormality
F6
00
F6-**: MCU-FAX communication trouble
MCU
10
FAX control PWB trouble
80
FAX control PWB communication trouble 
(Protocol)
81
FAX control PWB communication trouble 
(Parity)
82
FAX control PWB communication trouble 
(Over-run)
84
FAX control PWB communication trouble 
(Framing)
88
FAX control PWB communication trouble 
(Timeout)
99
Machine-FAX board language error
F9
00
F9-**: MCU-PRT communication trouble
MCU
10
Printer PWB trouble
80
Printer PWB communication trouble 
(Protocol)
81
Printer PWB communication trouble 
(Parity)
82
Printer PWB communication trouble 
(Overrun)
84
Printer PWB communication trouble 
(Framing)
88
Printer PWB communication trouble 
(Timeout)
99
Machine-PCL board language error
H2
00
Thermistor open detection
H3
00
Heat roller abnormally high temperature
H4
00
Heat roller abnormally low temperature
H5
01
5 continuous T10D(T20D) not-reaching 
JAM
02
Fusing thermistor abnormality
L1
00
Scanner feed trouble
L3
00
Scanner return trouble
L4
01
Main motor lock
11
Shifter motor trouble
L6
10
Polygon motor lock trouble
L8
01
Zero cross detection error
U2
04
EEPROM communication error
11
Counter check sum error
12
Adjustment value check sum error
20
Machine speed code data error
40
CRUM chip communication error
U7
00
RIC communication trouble
U9
00
U9-**: MCU-OPE communication trouble
OPE
80
Operation control PWB communication 
trouble (Protocol)
81
Operation control PWB communication 
trouble (Parity)
82
Operation control PWB communication 
trouble (Overrun)
84
Operation control PWB communication 
trouble (Framing)
88
Operation control PWB communication 
trouble (Time-out)
99
Operation panel language error
CE
00
The other communication error has 
occurred.
Network
01
The print server card (AR-NC3D) is not 
installed or defective.
Network
02
The specified mail server or the FTP 
server is not found.
Network
03
The specified server does not 
correspond during image transmission.
Network
04
The entered account name of the FTP 
server or the password is invalid.
Network
05
The entered directory of the FTP server 
is invalid.
Network
EE
EL
Developer adjustment trouble (Over-
toner abnormality)
EU
Developer adjustment trouble (Under-
toner abnormality)
PF
00
RIC copy inhibit signal received
Trouble 
code
Trouble contents
Trouble 
detection
Main 
code
Sub 
code
Page of 58