AR-235 (serv.man9). Adjustments, setting Simulation Trouble code list - Sharp Copying Equipment Service Manual (repair manual). Page 31

Read Sharp AR-235 (serv.man9) Service Manual online

AR-235/275 SIMULATION - 22
Operation/procedure (Pattern 1)
Used  to  set  whether  the  trouble  history  of  SIM  22-4  is  displayed  as
one-time  trouble  or  as  a  number  of  times  of  troubles  continuously
occurred when two or more troubles of the same kind occurred. 
Enter the set value with 10-key, and press [OK] key.
Operation/procedure (Pattern 1)
Input the set value with the 10-key and press the [OK] key.
Note: Executable only with SRU (AR models).
Operation/procedure (Pattern 1)
Input the set value with the 10-key and press the [OK] key.
Note: Executable only with CRU (DM models).
Operation/procedure (Pattern 1)
Input the set value with the 10-key and press the [OK] key.
Note: Executable only with CRU (DM models).
Operation/procedure (Pattern 1)
Input the set value with the 10-key and press the [OK] key.
Note: Executable only when the finisher is installed.
Operation/procedure (Pattern 1)
Input the set value with the 10-key and press the [OK] key.
Operation/procedure (Pattern 1)
Input  the  set  value  with  the  10-key  and  press  the  [OK]  key,  and  the
LCD contrast will be immediately changed and displayed.
Display items
Setting range
Default
Japan, SEC, SECL, 
SCA, SEF, Taiwan
Others
0:OFF
0-1
0
1
1:ON
26-35
Purpose
Setup
Function 
(Purpose)
Used to set the mode of trouble memory.
Item
Specifications
Display item
Content
Set range
Default
0:ONCE
When two or more troubles 
occur, only one is registered.
0-1
0
1:ANY
All the troubles occurred are 
registered. 
26-36
Purpose
Setting
Function 
(Purpose)
Used to set whether to stop when the maintenance life 
is reached.
Item
Operation
Display items
Content
Setting range
Default
0:STOP
Stop
0-1
1
1:NON STOP
Non stop
26-37
Purpose
Setting
Function 
(Purpose)
Used to set whether to stop when the developer life is 
reached.
Item
Operation
Display items
Content
Setting range
Default
0:STOP
Stop
0-1
0
1:NON STOP
Non stop
Sim26-35 TROUBLE
TROUBLE MODE      0
(0:ONCE 1:ANY)
     [  0-  1]    
0
Sim26-36 MAINTESTOP
MAINTENANCE OVER  0
  (0:STOP
   1:NON STOP)
     [  0-  1]    
0
Sim26-37 DEVE. STOP
DEVE. LIFE OVER   0
  (0:STOP
   1:NON STOP)
     [  0-  1]    
0
26-38
Purpose
Setting
Function 
(Purpose)
Used to set whether to stop when the drum life is 
reached.
Item
Operation
Display items
Content
Setting range
Default
0:STOP
Stop
0-1
0
1:NON STOP
Non stop
26-46
Purpose
Setting
Function 
(Purpose)
Used to set whether to meet with the output direction of 
images regardless of the mode when installing the 
finisher.
Item
Operation
Display items
Content
Setting range
Default
0:OFF
Setting No
0-1
0
1:ON
Setting Yes
26-50
Purpose
Setting
Function 
(Purpose)
Used to set whether to use the black/white reverse 
function.
Item
Operation
Display 
items
Content
Setting 
range
Default
0:ON
Enable
0-1
0
1:OFF
Disable
26-54
Purpose
Setting
Function 
(Purpose)
Used to set the PWM duty (brightness) at the center 
value of the LCD contrast.
Item
Operation
Setting range
30-70
Default
50
Sim26-38 DRUM STOP
DRUM LIFE OVER    0
  (0:STOP
   1:NON STOP)
     [  0-  1]    
0
Sim26-46 OUT DIR
OUT DIRECTION     0
  (0:OFF 1:ON)
     [  0-  1]    
0
Sim26-50 B/W REV.
B/W REVERSE       0
  (0:ON 1:OFF)
     [  0-  1]    
0
Sim26-54 LCD DUTY
LCD PWM DUTY      0
     [ 30- 70]    
0
Page of 58
Display