AR-235 (serv.man9). Adjustments, setting Simulation Trouble code list - Sharp Copying Equipment Service Manual (repair manual). Page 32

Read Sharp AR-235 (serv.man9) Service Manual online

AR-235/275 SIMULATION - 23
Operation/procedure (Pattern 1)
Input the set value with the 10-key and press the [OK] key.
If a model different from CPM setup (22cpm or 27cpm) of BOOT is set,
a system error will occur after canceling the simulation. 
Operation/procedure (Pattern 1)
Input the set value with the 10-key and press the [OK] key.
This setup varies in connection with SIM 26-6 (Destination setup).
Operation/procedure (Pattern 1)
Input the set value with the 10-key and press the [OK] key.
Operation/procedure
Current memory is displayed in PRESENT column.
Enter a value (max. 8 digits) with the 10-key, and press the [OK] key.
The input number is displayed instead of  "NEW".
The set value is stored and "PRESENT" of LCD is revised.
Operation/procedure
The operating conditions of sensors and detectors in the different sec-
tions than the paper  feed section of the machine   are displayed.  The
active sensors and detectors are highlighted.
26-57
Purpose
Setting
Function 
(Purpose)
Used to set the model code.
Item
Operation
Display items
Setting range
Default
1:AR-235
1-10
1
2:AR-255S
3:AR-255P
4:AR-255F
5:AR-255FP
6:AR-275
7:AR-N275
8:DM-2305
9:DM-2515
10:DM-2705
26-60
Purpose
Setting
Function 
(Purpose)
Used to set enable/disable of the FAX mode key when 
FAX is not installed. (When FAX is installed, the FAX 
mode is enabled regardless of this setup.)
Item
Operation
Display 
items
Content
Setting 
range
Default
JAPAN, 
SEC, SECL, 
SUK, SCA
Others
0:ON
Effective (The 
message with FAX 
uninstalled is 
displayed.)
0-1
0
1
1:OFF
Disable (Error Beep)
27
27-1
Purpose
Setting
Function 
(Purpose)
Used to set PC/MODEM communication trouble (U7-
00) detection Yes/No.
Section
Communication (RIC/MODEM)
Item
SpecificationsOperation mode 
(Common)
Sim26-57 MACHINE
MACHINE CODE      1
(1:AR-235
2:AR-255S
1/5 [   1-10]     
1
Sim26-60  FAX KEY
FAX KEY SETTING   0
  (0:ON 1:OFF)
     [  0-  1]    
0
Display 
items
Content
Setting 
range
Default
0:OFF
In case of the communication 
trouble, U7-00 is not displayed.
0-1
0
1:ON
In case of the communication 
trouble, U7-00 is displayed.
27-5
Purpose
Setting
Function 
(Purpose)
Used to enter the TAG No. of the copier.
Item
Data
30
30-1
Purpose
Operation test/check
Function 
(Purpose)
Used to check the operation of sensors and detectors 
in the sections other than the paper feed section of the 
copier and the related circuit. (The operation of 
sensors and detectors can be monitored with the 
LCD.)
Section
Others
Item
Operation
PPD1H
PS paper detection 1 sensor
PPD1L
PS paper detection 2 sensor
PPD2
Duplex sensor
POD1
1st paper exit paper out sensor
DVCH
Developing cartridge detection sensor
DRST
Drum intial detection sensor
DSWR1
Interlock switch (side door)
SFTHP
Shifter home position sensor
POD2
2nd paper exit paper out sensor
TOPF
2nd paper exit full detection sensor
DSWR0
2nd paper exit cover open/close detection sensor
LOEMP
1st paper exit empty detection sensor
Sim27-1 U7-00 SET.
DISABLE U7-00     0
  (0:OFF 1:ON)
     [  0-  1]    
0
Sim 27-5 TAG# SET.
TAG# SETTING
PRESENT :
NEW     :
12345678
Sim30-1 MAIN SENSOR
PPD1H PPD1L 
PPD2
POD1  DVCH  DRST
DSWR1 
SFTHP
 POD2
TOPF  DSWR0 LOEMP
Page of 58
Display

Click on the first or last page to see other AR-235 (serv.man9) service manuals if exist.