AR-235 (serv.man9). Adjustments, setting Simulation Trouble code list - Sharp Copying Equipment Service Manual (repair manual). Page 29

Read Sharp AR-235 (serv.man9) Service Manual online

AR-235/275 SIMULATION - 20
A4/LT (8.5" x 11") detection enable/disable setup
In the inch series, Letter is detected as A4; in the AB series, A4 is detected as Letter.
Detection size when A4/LT (8.5" x 11") document/paper is used.
Operation/procedure (Pattern 1)
Set the auditor.
Operation/procedure (Pattern 2)
Used  to  set  the  count  up  number  (1  or  2)  when  an  A3/WLT  paper
passes through.
For  the  drum  counter  and  the  developer  counter,  double  count  is
employed unconditionally.
(Target counter selection)
Used to set the count up number of the selected counter.
Operation/procedure (Pattern 1)
Select the destination.
Operation/procedure
The current setup is displayed with ON or OFF.
Enter an input (20 digits) of the NETWORK soft key and press the [OK]
key, and the collating result is displayed with OK or NG.
When "0" is entered to the soft key, it is treated as a trial setup.
Set value
Setup
Remarks
0
Detection invalid
Default
1
Detection valid
Employed unit
Destination
Document size
Set value
0
(Invalid)
1
(Valid)
Document
Document 
table/SPF
AB series
A4
A4
LT (8.5”  x 11”)
LT (8.5”  x 11”)
A4
LT (8.5”  x 11”)
Inch series
A4
LT (8.5”  x 11”)
A4
LT (8.5”  x 11”)
LT (8.5”  x 11”)
A4
Paper
Machine paper 
feed cassette
All destinations
Set with key operations.
Manual paper 
feed tray
All destinations
Regardless of the simulation 
setup.
26-3
Purpose
Setting
Function 
(Purpose)
Used to set the specifications of the auditor. Setting 
must be made depending on the use condition of the 
auditor.
Section
Auditor
Item
Specifications
Display 
items
Content
Setting 
range
Default
0:P10
Built-in auditor mode
0-2
0
1:VENDOR
Coin vendor mode
2:OTHER
Others
26-5
Purpose
Setting
Function 
(Purpose)
Used to set the count mode of the total counter and the 
maintenance counter.
Item
SpecificationsCounter
1:TOTAL COUNTER
Total
2:MAINTE COUNTER
Maintenance
1:SINGLE COUNT
Single count
2:DOUBLE COUNT
Double count
Setting range
1-2
Default
2
(Initial screen)
(Input screen)
Sim26-3 AUDITOR SET
AUDITOR           0
  (0:P10 1:VENDOR
         2:OTHER)
     [  0-  2]    
0
Sim26-5 COUNT MODE
1:TOTAL COUNTER   1
2:MAINTE COUNTER  1
                  
2
Sim26-5 COUNT MODE
2:MAINTE COUNTER  1
  (1:SINGLE COUNT
   2:DOUBLE COUNT)
     [  1-  2]    
1
26-6
Purpose
Setting
Function (Purpose)
Used to set the specifications depending on 
the destination.
Item
SpecificationsDes
tination
Display 
items
Content
Setting 
range
Default
0:JAPAN
Japan
0-13
0
1:SEC
SEC
2:SECL
SECL
3:SEEG
SEEG
4:SUK
SUK
5:SCA
SCA
6:SEF
SEF
7:INEG
EX inch series
8:ABEG
EX AB series
9:INEF
EX inch series (FC)
10:ABEF
EX AB series (FC)
11:CHINESE
China
12:TAIPEI
Taiwan
13:SEEG2
SEEG2
26-10
Function 
(Purpose)
Used to enter the Software Key for the Network 
Scanner. (Setup is allowed only when the PCL board is 
installed.
(Initial screen)
(In case of OK)
(In case of NG)
Sim26-6 DESTINATION
DESTINATION       0
(0:JAPAN 1:SEC
2:SECL 3:SEEG 4:SUK
1/3  [  0- 13]   
 0
Sim26-10 SCANNERKEY
  SCANNER KEY  ON
     
----------
     
----------
Sim26-10 SCANNERKEY
  SCANNER KEY  OK
     
----------
     
----------
Sim26-10 SCANNERKEY
  SCANNER KEY   NG     
     
----------
Page of 58