4) Change the set value and press the start button.
When the set value is made greater, the image lead edge reference position is shifted forward.
When the set value is made smaller, the image lead edge reference position is shifted backward.
(Note) If this adjustment is not made properly, when the copy magnification ratio is changed, the copy image position
varies for the paper lead edge position.
5) Select the adjustment mode lead edge void area with the copy picture quality mode select key. (The currently
set adjustment value is displayed on the copy quantity display.)
6) Change the set value and press the start button. 
7) Select the adjustment mode rear edge void area with the copy quality mode select key.
(The currently set adjustment mode is displayed on the copy quantity display.)
8) Change the set value and press the start button. 
The adjustment value can be set in the range of 0 ~ 99.
Note
50 - 10
Purpose
Adjustment
Function
(Purpose)
Used to adjust the main scanning direction print image position. (Main scanning direction void area adjustment)
Section
ICU
Item
Picture quality
Operation/
Procedure
1) Select the adjustment item with the copy image mode select key.
Adjustment mode
Adjustment mode display (ON)
Note
Main scanning direction image
position
Photo copy mode lamp
Main scanning direction image
position (SPF mode)
Auto/Photo/Manual copy mode lamp
Left void area
Auto copy mode lamp
Right void area
Manual copy mode lamp
2) To change the copy image position in the main scanning direction for the paper in a copy mode (to change
the main scanning direction void area), change the adjustment value and press the start button. 
(The adjustment value is stored and a copy is made corresponding to the setting.)
The adjustment value can be set in the range of 0 ~ 99.
When the adjustment value is changed by "1," the copy image position is shifted by 0.1mm in the main
scanning direction for the paper. 
When the main scanning direction copy magnification ratio is adjusted with SIM 48-1 (auto mode), this
adjustment is automatically performed and there is no need to enter the adjustment value with this simulation.
If the adjustment is not made properly, use this simulation to make a manual adjustment. (Except for the SPF
mode. In the case of the SPF mode, the adjustment with this simulation is required.)
3) To change the left and the right void areas, select the adjustment mode, change the adjustment value and
press the start button. 
(The adjustment value is stored and a copy corresponding to the setting is made.)
The adjustment value can be set in the range of 0 ~ 99.
When the adjustment value is changed by "1," the void area is changed by 0.1mm,
Note
61
61 - 3
Purpose
Operation test/check
Function
(Purpose)
Used to check the operation of the scanner (writing) section.
Section
Laser (Exposure)
Item
Operation
Operation/
Procedure
While laser beams are outputted, the scanner(writing) motor rotates for 30 sec.
At that time, the zoom mode display lamp lights up for 100msec every time when the laser beam sensor detects
laser beam,
Note