AL-840 (serv.man7). AL800 840 Service Manual-Simulation codes - Sharp Copying Equipment Service Manual (repair manual). Page 13

Read Sharp AL-840 (serv.man7) Service Manual online

16
16 - 0
Purpose
Clear/Cancel (Trouble etc.)
Function
(Purpose)
Used to cancel the self diag U2 trouble.
Section
Item
Trouble
Error
Operation/
Procedure
Note
22
22 - 5
Purpose
User data output/Check (Display/Print)
Function
(Purpose)
Used to check the total counter value.
Section
Item
Counter
Total
Operation/
Procedure
The total print counter value is displayed in 3 digits of each two times. 
The display is made repeatedly and continuously.
(Example) Total print counter value = 12345
(Display content) 
012
Blank
345
Blank
012
(Display time) 
0.7sec 
0.3sec (short)
0.7sec
1.0sec (long)
0.7sec
Note
22 - 12
Purpose
Operation data output/Check (Display/Print)
Function
(Purpose)
Used to check the print count value of the photoconductor.
Section
Image process
(Photoconductor/Developing/Transfer/Cleaning)
Photo conductor
Item
Counter
Operation/
Procedure
The display system and the method are the same as those of SIM 22-5 (Total print counter display).
Note
22 - 14
Purpose
Others
Function
(Purpose)
Used to check the ROM version.
Section
PCU
Item
Software
Operation/
Procedure
The ROM version on the MCU PWB is displayed in 3 digits on the copy quantity display. 
If any trouble occurs in the software operation, check the version with this simulation.