AL-840 (serv.man7). AL800 840 Service Manual-Simulation codes - Sharp Copying Equipment Service Manual (repair manual). Page 22

Read Sharp AL-840 (serv.man7) Service Manual online

2. User program 
A. Outline
The user program is used to realize the machine conditions according
to the user’s own requirements. 
B. Operating procedure
1) Keep pressing the left and right copy density adjustment keys at
the same time at the same time for over 5 sec. (The copy quantity
display turns off. The photoconductor cartridge replacement lamp,
the toner cartridge replacement lamp, and the paper jam lamp
blink. The machine enters the user program mode.) (Ready lamp
OFF)
2) Set the user program number with the value set key (digit of 10).
(The user program number is displayed on the copy quantity dis-
play.)
3) Press the start key. 
(The machine enters the program mode set in procedure 2).)
4) Use the value set key (digit of 1) to enter the desired set value.
(The set value is displayed on the copy quantity display.)
5) Press the start button.
After entering a user program mode, press the clear key once, and
the other user program numbers are ready to be selected.
To cancel the user program mode, press the left or right copy density
adjustment key.
Operation flow of user program
START (Normal mode)
Keep pressing the left and
right copy density adjustment 
keys at the same time for 5 sec.
The machine enters the user
program mode.
(The copy quantity display
turns off;the photoconductor
cartridge replacement lamp,
the toner cartridge replacement
lamp, and the paper jam lamp
blink.
(Ready lamp goes off.)
Set the user program number 
with the value set key. 
(The user program number 
is displayed on the copy 
quantity display.) 
Press the start key. 
(The machine enters the set 
program mode.)
Enter the set value 
corresponding to the set 
content with the value set key.
Press the left or the 
right copy density
adjustment key.
Press the clear key.
Do you
want to cancel the
user program
mode ?
Another user
program mode is
selected.
The set content of currently 
set user program mode is 
changed.
YES
NO
YES
NO
C. Content
Program No
Set value
Content
1
0
OFF
Auto clear time setting
This setting is linked with the shift time from the off-line mode to the on-line
mode.
When the set value is "0," however, the time is 30 sec.
1
30 sec
2
60 sec
3
90 sec
4
120 sec
2
0
30 sec
Pre-heat mode shift time setting
1
60 sec
2
90 sec
3
0
2 min
Power shut down shift time setting
1
5 min
2
15 min
3
30 min
4
60 min
5
120 min
5
0
YES
Power shut down YES/NO setting
1
NO
9
0
OFF
Paper width detection ON/OFF setting
1
ON
8 – 22
Page of 22
Display