Read Sharp AL-840 (serv.man7) Service Manual online
22 - 21
Purpose
Operation data output/Check (Display/Print)
Function
(Purpose)
(Purpose)
Used to check the count of use (count of scanning) of the scanner (reading) unit.
Section
Optical (Image scanning)
Item
Counter
Operation/
Procedure
Procedure
The display system and the method are the same as those of SIM 22-5 (Total print counter display).
Note
24
24 - 7
Purpose
Data clear
Function
(Purpose)
(Purpose)
Used to clear the photoconductor drum counter.
Section
Image process
(Photoconductor/Developing/Transfer/Cleaning)
(Photoconductor/Developing/Transfer/Cleaning)
Photo conductor
Item
Counter
Operation/
Procedure
Procedure
Note
24 - 13
Purpose
Data clear
Function
(Purpose)
(Purpose)
Used to clear the count of use (count of scanning) of the scanner (reading) unit.
Section
Optical (Image scanning)
Item
Counter
Operation/
Procedure
Procedure
Note
25
25 - 1
Purpose
Operation test/check
Function
(Purpose)
(Purpose)
Used to check the operation of the main drive (excluding the scanner (reading) section) section.
Section
DRIVE
Item
Operation
Operation/
Procedure
Procedure
The main motor rotates for 30 sec.
During the motor rotation, one of the following two operations is performed depending on installation of the
developer cartridge.
During the motor rotation, one of the following two operations is performed depending on installation of the
developer cartridge.
1) When the developer cartridge is installed:
(The following high voltages are outputted.)
*
Main charger voltage
*
Transfer charger voltage
*
Developer bias voltage
2) When the developer cartridge is not installed:
The high voltage is not outputted and the main motor rotates only.
Note
8 – 14