Read Sharp AL-840 (serv.man7) Service Manual online
6
6 - 1
Purpose
Operation test/check
Function
(Purpose)
(Purpose)
Used to check the operation of the paper feed (clutch, solenoid and its control circuit.
Section
Paper transport
Item
Operation
Operation/
Procedure
Procedure
The paper feed clutch solenoid repeats ON for 500msec and OFF for 500msec each 20 times.
Note
7
7 - 1
Purpose
Operation test/check
Function
(Purpose)
(Purpose)
Used to check the warm up time and the operation of all the units and to make aging with copying. Each section
can be checked during copying.
can be checked during copying.
Section
Others
Item
Operation
Operation/
Procedure
Procedure
1) After completion of simulation, warming up is started.
2) Counting is made every second and the count value is displayed.
3) After completion of warming up, counting is stopped and the ready lamp is lighted.
4) Press the clear key. (Once)
5) Set the copy quantity.
6) Press the start key.
Copying is made repeatedly to make the set quantity of copy.
Note
7 - 2
Purpose
Operation test/check
Function
(Purpose)
(Purpose)
Used to check the warm up time and the operation of all the units and to make aging with copying. Each section
can be checked during copying. (In this simulation, the detection functions of paper presence/empty and a paper
jam are disabled.)
can be checked during copying. (In this simulation, the detection functions of paper presence/empty and a paper
jam are disabled.)
Section
Others
Item
Operation
Operation/
Procedure
Procedure
Basically the same operation is performed as SIM 7-1. However, paper empty or presence and paper jam are
ignored.
ignored.
Note
7 - 6
Purpose
Operation test/check
Function
(Purpose)
(Purpose)
Used to check the warm up time and the operation of all the units and to make aging (intermittent operation) with
copying. Each section can be checked during copying.
copying. Each section can be checked during copying.
Section
Others
Item
Operation/
Procedure
Procedure
Basically the same operation is performed as SIM 7-1.
Similarly with SIM 7-1, copying is made in the unit of the set quantity, however there is an 3sec interval between
the set quantities.
Similarly with SIM 7-1, copying is made in the unit of the set quantity, however there is an 3sec interval between
the set quantities.
Note
8 – 11