Read Sharp AL-2040 (serv.man2) Service Manual online
AL-2040 SIMULATION, TROUBLE CODES 10 - 7
26
42
Transfer ON timing control setup
(Operation/Procedure)
1. When this simulation is executed, the currently set code number is displayed.
2. Enter the code number and press the START key, and the setting will be changed. (For any number different from the
(Operation/Procedure)
1. When this simulation is executed, the currently set code number is displayed.
2. Enter the code number and press the START key, and the setting will be changed. (For any number different from the
following ones, the default time is automatically set.)
43
Side void setup
(Operation/Procedure)
1. When this simulation is executed, the currently set code number of the side void amount is displayed.
2. Enter the code number and press the START key. The setting is changed.
(Operation/Procedure)
1. When this simulation is executed, the currently set code number of the side void amount is displayed.
2. Enter the code number and press the START key. The setting is changed.
54
γ life correction setup
(Operation/Procedure)
1. When this simulation is executed, the currently set code number is displayed.
2. Enter the code number and press the START key. The setting is changed.
(Operation/Procedure)
1. When this simulation is executed, the currently set code number is displayed.
2. Enter the code number and press the START key. The setting is changed.
62
Energy-save mode copy lamp setup
Used to set half-ON (50%)/OFF of the copy lamp in the pre-heat mode.
When this simulation is executed, the current setup of the code number is displayed. Enter the code number and press the
PRINT switch to enable the setup.
Used to set half-ON (50%)/OFF of the copy lamp in the pre-heat mode.
When this simulation is executed, the current setup of the code number is displayed. Enter the code number and press the
PRINT switch to enable the setup.
30
01
Paper sensor status display
Indicates the paper sensor status using the lamps on the operation panel.
Indicates the paper sensor status using the lamps on the operation panel.
Main
code
code
Sub
code
Content
Code number
Setting
0
Default (236 msec)
1
– 20 msec
2
– 18 msec
3
– 16 msec
4
– 14 msec
5
– 12 msec
6
– 10 msec
7
– 8 msec
8
– 6 msec
9
– 4 msec
10
– 2 msec
Code number
Setting
11
Default (236 msec)
12
+2 msec
13
+4 msec
14
+6 msec
15
+8 msec
16
+10 msec
17
+12 msec
18
+14 msec
19
+16 msec
20
+18 msec
21
+20 msec
Code number
Setting
0
0 mm
1
0.5 mm
2
1.0 mm
3
1.5 mm
4
2.0 mm * Default
5
2.5 mm
6
3.0 mm
7
3.5 mm
8
4.0 mm
9
4.5 mm
10
5.0 mm
Code number
γ life correction
0
OFF
1
ON
Code number
Setup
0
Copy lamp OFF
1
Copy lamp half-ON (50%) * Default
Sensor name
Display lamp
Before-resist paper sensor (PPD1)
Developer cartridge replacement lamp
Fusing section paper sensor (PPD2)
JAM lamp
Paper exit sensor (POD)
Photoconductor cartridge replacement lamp
2nd CS paper sensor (PPD3)
2nd cassette lamp
New drum cartridge sensor (PUIS)
Zoom lamp