AL-2040 (serv.man2). Service Manual - Sharp Copying Equipment Service Manual (repair manual). Page 68

Read Sharp AL-2040 (serv.man2) Service Manual online

AL-2040  SIMULATION, TROUBLE CODES  10 - 8
41
06
OC cover float detection level adjustment <SPF model only>
When this simulation is executed, the current set value is displayed.
When ENTER/START key is pressed, the mirror base unit moves to the SPF scanning position and the OC cover float 
detection level (number of pixels between black lines) is acquired and displayed.
The value (0000) is displayed on the 7seg in 2 digits for each.
When the mirror base unit returns to the home position, the acquired value is displayed.
If the value is not acquired, an error is displayed as shown below. (Default: 0)
The status display is as shown below.
The JAM lamp is lighted. (The 7seg display remains to the original value.)
Note that the OC cover must be closed when executing this simulation.
∗ When the value is 0, float detection is not performed in a normal job.
When C key is pressed, the display returns to the sub code input standby state.
07
OC cover float detection margin setting <SPF model only>
For the number of pixels between black markers on the SPF scanning position saved in SIM 41-06 (OC cover float detection 
level adjustment), if the number of pixels between the markers when processing float detection is less than the number of 
pixels set with this simulation, it is judged as the float error.
In addition, if the set value of this simulation is 0, no float error occurs.
When this simulation is executed, the current set value is displayed.
Enter the adjustment value with UP/UP key, and press START key to save the entered value. The display returns to the sub 
code input standby mode.
Set range: 0 – 99
Default: 30 (30 pixels)
43
01
Fusing temperature setting (Normal copy)
Used to set the fusing temperature of 3rd or later sheet. (For 1st and 2dns sheets, SIM 43-14 is used.)
When this simulation is executed, the currently set code number is displayed.
Enter the code number with UP/UP key and press START key. The entered value is saved and the display returns to the sub 
code input standby state.
The density select key is used to select the mode. The set value of the selected mode is displayed on the 7seg.
∗ The cassette feed and the manual feed are controlled similarly.
04
Fusing temperature setting in multi copy
From the 20th sheet and later, the fusing temperature is changed over from the level set with SIM 43-1 to the level set with this 
simulation.
When this simulation is executed, the currently set code number is displayed.
Enter the code number with UP/UP key and press START key. The entered value is saved and the display returns to the sub 
code input standby state.
The density select key is used to select the mode. The set value of the selected mode is displayed on the 7seg.
∗ The cassette feed and the manual feed are controlled similarly.
Main 
code
Sub 
code
Content
Code number
Set temperature (°C)
0
170
1
175
2
180
3
185
4
190
5
195 (* Default)
6
200
7
205
8
210
Mode
Lamp ON
Main cassette paper feed & 2nd cassette paper feed
AE mode lamp
Manual paper feed
TEXT mode lamp
Code number
Set temperature (°C)
0
165
1
170
2
175
3
180
4
185
5
190
Mode
Lamp ON
Default
Main cassette paper feed & 2nd cassette paper feed
AE mode lamp
3
Manual paper feed
TEXT mode lamp
3
Main cassette paper feed & 2nd cassette paper feed (small-size)
PHOTO mode lamp
3
Manual paper feed (small-size)
AE, TEXT mode lamp
3
Page of 92