AL-2040 (serv.man2). Service Manual - Sharp Copying Equipment Service Manual (repair manual). Page 70

Read Sharp AL-2040 (serv.man2) Service Manual online

AL-2040  SIMULATION, TROUBLE CODES  10 - 10
43
15
Postcard size paper fusing control cycle sync setting
When this simulation is executed, the currently set code number is displayed.
Change the setting with UP/UP key, and press START key to write the setting to the EEPROM. (Setting range: 0 – 20, default: 
0)
∗ When set to "0," the setting is canceled and the fusing temperature control and the paper pass timing are not synchronized. 
The conventional control (control same as the other paper) is performed.
∗ When set to "1" – "20," the postcard pass is synchronized with the fusing temperature control cycle, providing stable fusing 
performance. However, CPM is reduced.
∗ When set to "1" – "20," if "Set value x 0.5°C + Temperature control level," the fusing heater lamp is turned OFF.
46
01
Copy density adjustment (300dpi)
Used to set the copy density in each mode.
(Operating procedure)
When this simulation is executed, warm-up and shading operations are performed and the current setup is displayed in two 
digits (default: 50).
Change the setup value with the copy quantity keys. Press the PRINT switch and a copy is made according to the new setup.
The greater the setup value is, the darker the copy is. The smaller the setup value is, the brighter the copy is. Only EXP.3 copy 
is made in this simulation. When set to a darker level, Exp.1 and Exp.5 copies also become darker. When set to a brighter 
level, Exp.1 and Exp.5 copies also become brighter. Press the CLEAR key to save the setup and exit from the simulation 
mode.
Use the copy mode select key to select a copy mode. The setup value of the selected copy mode is displayed on the copy 
quantity display. (adjustment range: 1 – 99) 
02
Copy density adjustment (600dpi)
Used to set the copy density in each mode.
(Operation/Procedure)
When this simulation is executed, the machine performs warm-up and shading, and the current setup value is displayed in two 
digits. (Default: 50)
Use the copy quantity key to change the setup value, and press the PRINT switch to make a copy with the new setup.
The greater the setup value is, the darker the copy is, and vise versa. Only EXP.3 copy is made. If it is set to a darker density, 
EXP.1 and EXP.5 copies also become darker. If it is set to a brighter density, they also become brighter.
When the CLEAR key is pressed, the entered setup value is saved and the simulation is terminated.
Any copy mode can be selected with the copy mode select key. The setup value of the selected copy mode is displayed on the 
copy quantity display. (Setup range: 1 – 99)
Main 
code
Sub 
code
Content
Code number
Sync setting
Fusing heater lamp OFF timing temperature
0
Cancel
– (* Default)
1
Setting
+0.5°C
:
:
6
+3.0°C
:
:
20
+10.0°C
Copy mode
Display lamp
AE mode (300dpi)
AE mode lamp
TEXT mode (300dpi)
TEXT mode lamp
PHOTO mode
PHOTO mode lamp
TS mode (TEXT) (300dpi)
TEXT mode lamp & PHOTO mode lamp
TS mode (AE) (300dpi)
AE mode lamp & PHOTO mode lamp
Copy mode
Display lamp
AE mode (600dpi)
AE mode lamp
TEXT mode (600dpi)
TEXT mode lamp
PHOTO mode
PHOTO mode lamp
TS mode (TEXT) (600dpi)
TEXT mode lamp & PHOTO mode lamp
TS mode (AE) (600dpi)
AE mode lamp & PHOTO mode lamp
Page of 92
Display

Click on the first or last page to see other AL-2040 (serv.man2) service manuals if exist.