AL-1622 (serv.man11). Simulations - Sharp Copying Equipment Service Manual (repair manual). Page 4

Read Sharp AL-1622 (serv.man11) Service Manual online

AL-1611/AL-1622
SIMULATIONS
8 – 4
*
2: Display after clearing each counter 000 
(0.75 sec) 
3
 Blank (0.35 sec) 
3
 000 (0.75 sec) 
3
 Blank (1.0 sec) 
3
 Repetition
7
6
Intermittent aging
After completion of warmup, counting is stopped and the ready lamp is 
lighted. When the copy quantity is entered and the start key is pressed, copy-
ing is made to make the set quantity of copies. After 3 sec standby, copying is 
made again to make the set quantity of copies. After that this operation is 
repeated. The paper size does not matter.
1 ~ 99
8
Warmup time display
Execute the simulation input with the copier side cover open, then close the 
side cover, and the machine will starts warming up. Warm up time is counted 
up every 2nd and it is displayed.
1 ~ 99
8
1
Developing bias voltage 
output check
Used to out put the developing bias for 30 sec. For the adjustment procedure 
of the developing bias, refer to the previous descriptions.
2
Main charger voltage output 
check (Grid bias high mode)
Used to output the main charger grid bias voltage at the high mode for 30 sec. 
For the adjustment procedure of the main charger grid bias voltage, refer to 
the previous descriptions.
3
Main charger voltage output 
check (Grid bias low mode)
Used to output the main charger grid bias voltage at the low mode for 30 sec. 
For the adjustment procedure of the main charger grid bias voltage, refer to 
the previous descriptions.
6
Transfer charger voltage 
check
Used to output the transfer charger voltage for 30 sec. For the adjustment pro-
cedure of the transfer charger voltage, refer to the previous descriptions.
9
1
Duplex motor forward rota-
tion operation check 
<Not Used>
Used to rotate the duplex motor forward for 30 sec.
2
Duplex motor reverse rota-
tion operation check 
<Not Used>
Used to rotate the duplex motor reversely for 30 sec.
4
Duplex motor rotation speed 
adjustment 
<Not Used>
The currently set duplex motor rotation speed set value is displayed. When 
the set value is entered and the start key is pressed, the set value is stored.
6
1  ~  13
5
Duplex motor switchback 
time adjustment
<Not Used>
The currently set duplex motor switchback time set value is displayed. When 
the set value is entered and the start key is pressed, the set value is stored.
50
18 ~ 76
10
Toner motor operation check Used to operate the toner motor for 30 sec.
Note: If this simulation is executed with the toner hopper installed, toner is
automatically supplied to the developer. Be careful of overtoner.
14
Trouble (except for U2) 
cancel
Used to cancel troubles except for U2.
16
U2 trouble cancel
Used to cancel U2 trouble.
20
1
Maintenance counter clear
Used to clear the maintenance counter. 
*
2
21
1
Maintenance cycle setting
Used to display the currently set maintenance cycle at the numbers shown at 
right. When the set value is entered and the start key is pressed, the set value 
is stored.
2
0  ~  7
Main 
code
Sub 
code
Contents
Details of operation
Initial 
value
Set range
Key operation
Copy quantity setting: Copy quantity keys
Key operation
Duplex motor rotation speed set value: Copy quantity keys
Key operation
Duplex motor switchback time set value: Copy quantity keys
Key operation/Display
0: 2500 sheets
1: 5000 sheets
2: 25000 sheets (When toner save is ON)
3: 50000 sheets (When toner save is ON)
4: 150000 sheets
5: FREE (999999 sheets)
6: 10000 sheets
7: 7500 sheets
Page of 11
Display

Click on the first or last page to see other AL-1622 (serv.man11) service manuals if exist.