CRUM set value display
The currently set value of CRUM is displayed with the following numbers:
10
Model name setting
Used to set the model name of the machine used with the following numbers. 
After entering the set value, press the start key and the set value is stored.
0
0  ~  1
22
Language setting
Used to display the current setting of the language information with the num-
ber at right. After entering the set value, press the start key, and the set value
is stored.
1
0  ~  7
30
CE mark conformity control 
setting
Used to display the current setting of CE mark conformity control with the 
number at right. After entering the set value, press the start key, and the set 
value is stored.
1
0  ~  1
32
Fan rotation duty change 
state setup
The currently set fan motor rotation duty is displayed with the following num-
bers. After entering the set value, press the start key to store the set value.
0
0  ~  1
38
Cancel of stop at drum life 
over 
<Not Used>
The currently set value is displayed. After entering the set value, press the 
start key to store the set value.
1
0  ~  1
42
Transfer timing adjustment
After completion of warm up, shading is performed and the currently set trans-
fer timing adjustment value is displayed.
3
1, 3, 5, 7, 9
Main 
code
Sub 
code
Contents
Details of operation
Initial 
value
Set range
Key operation/Display
0: Not set
1: BTA-A
2: BTA-B
  3: BTA-C
99: Conv
Key operation/Display
0: AL-1611
1: AL-1622
Key operation/Display
0: Japanese
1: English
2: French
3: German
4: Italian
5: Dutch
6: Swedish
7: Spanish
Key operation/Display
0: CE mark control OFF
1: CE mark control ON
Key operation/Display
0: Operating 50%, standby 30%
1: Operating 80%, standby 50%
Key operation/Display
0: The machine stops at drum life over.
1: The machine does not stop at drum life over.
Key operation
Transfer timing adjustment value: Copy quantity keys
"1": 240 ms
"3": 260 ms
"5": 280 ms
"7": 300 ms
"9": 320 ms