AL-1566 (serv.man17). Service manual - Sharp Copying Equipment Service Manual (repair manual). Page 116

Read Sharp AL-1566 (serv.man17) Service Manual online

AL-1556/1566  TEST COMMAND, FAX SOFT SWITCH, TROUBLE CODES  10 - 40
S
W
5
1
Inhibited to use
0
2
0
3
G3 send data 
accumulation wait time
Bit No.
3
4
6sec
0
6sec
0
0
5sec
0
1
4
4sec
1
0
0
3sec
1
1
5
Pause time setup
Binary input
2sec
0 When a value outside 
the set range is set, 
the initial value is set.
6
Bit  No.
Set range
5
6
7
8
1 to 15sec
0
7
1
8
0
S
W
6
1
ECM
1: Yes
0: No
Yes
1
2
CED signal send
1: Yes
0: No
Yes
1
3
CSI transmission
1: Yes
0: No
Yes
1
4
DIS reception 
confirmation in G3 send
1: 2 times
0: Once in NFS reception, 
2 time in DIS reception
Once in NFS 
reception, 2 time 
in DIS reception
0
5
Inhibited to use
0
6
EOL detection timer
1: 25sec
0: 13sec
13sec
0
7
Countermeasure for 
echo in reception (CED 
tone send interval)
1: 500ms
0: 75ms
75ms
0
8
Countermeasure for 
echo in transmission 
(After reception of DIS, 
hold time up to signal 
send is set.)
1: 500ms
0: 200ms
200ms
0
S
W
7
1
Inhibited to use
0
2
Dial tone detection
1: Yes
0: No
No
0
3
Busy tone detection
1: Yes
0: No
Yes
1
4
Dial tone monitoring 
time
1: 10sec
0: 5sec
5sec
0
5
Inhibited to use
0
6
Max. length of reception 1: No limit
0: 1.5m
1.5m
0
7
Destination display time 
when one-touch key is 
pressed
Bit No.
7
8
2sec
0
When a value outside 
the set range is set, 
the initial value is set.
2sec
0
0
4sec
0
1
8
6sec
1
0
0
1
1
S
W
8
1
Memory transmission/
direct transmission 
default setup
1: Direct transmission
0: Memory transmission
Memory 
transmission
0
2
Proxy reception
1: Yes
0: No
Yes
1
3
Inhibited to use
0
4
Quick online send
1: Yes
0: No
Yes
1
5
Remote select function
1: Yes
0: No
Yes
1
Refer to User program 
“REMOTE 
RECEPTION 
SELECT”.
6
Number of times of 
CNG detection
Binary input
3 times
0 When a value outside 
the set range is set, 
the initial value is set.
7
Bit  No.
Set range
6
7
8
1 to 4 times
1
8
1
S
W
9
1
Print of total 
communication time 
and total pages
1: Yes
0: No
Yes
1
2
Inhibited to use
0
3
Ringing volume pattern 
number
Binary input
1
0 When a value outside 
the set range is set, 
the initial value is set.
4
Bit  No.
Set range
3
4
5
6
7
8
Pattern No. 1 to 35
0
5
0
6
0
7
0
8
1
SW 
NO.
Data 
No.
Item
Switch selection and contents of functions
Initial value
Remark
Page of 127