Read Sharp AL-1566 (serv.man17) Service Manual online
AL-1556/1566 TEST COMMAND, FAX SOFT SWITCH, TROUBLE CODES 10 - 40
S
W
5
1
Inhibited to use
0
2
0
3
G3 send data
accumulation wait time
accumulation wait time
Bit No.
3
4
6sec
0
6sec
0
0
5sec
0
1
4
4sec
1
0
0
3sec
1
1
5
Pause time setup
Binary input
2sec
0 When a value outside
the set range is set,
the initial value is set.
the initial value is set.
6
Bit No.
Set range
Set range
5
6
7
8
1 to 15sec
0
7
1
8
0
S
W
6
1
ECM
1: Yes
0: No
Yes
1
2
CED signal send
1: Yes
0: No
Yes
1
3
CSI transmission
1: Yes
0: No
Yes
1
4
DIS reception
confirmation in G3 send
confirmation in G3 send
1: 2 times
0: Once in NFS reception,
2 time in DIS reception
2 time in DIS reception
Once in NFS
reception, 2 time
in DIS reception
0
5
Inhibited to use
0
6
EOL detection timer
1: 25sec
0: 13sec
13sec
0
7
Countermeasure for
echo in reception (CED
tone send interval)
echo in reception (CED
tone send interval)
1: 500ms
0: 75ms
75ms
0
8
Countermeasure for
echo in transmission
(After reception of DIS,
hold time up to signal
send is set.)
echo in transmission
(After reception of DIS,
hold time up to signal
send is set.)
1: 500ms
0: 200ms
200ms
0
S
W
7
1
Inhibited to use
0
2
Dial tone detection
1: Yes
0: No
No
0
3
Busy tone detection
1: Yes
0: No
Yes
1
4
Dial tone monitoring
time
time
1: 10sec
0: 5sec
5sec
0
5
Inhibited to use
0
6
Max. length of reception 1: No limit
0: 1.5m
1.5m
0
7
Destination display time
when one-touch key is
pressed
when one-touch key is
pressed
Bit No.
7
8
2sec
0
When a value outside
the set range is set,
the initial value is set.
the set range is set,
the initial value is set.
2sec
0
0
4sec
0
1
8
6sec
1
0
0
1
1
S
W
8
1
Memory transmission/
direct transmission
default setup
direct transmission
default setup
1: Direct transmission
0: Memory transmission
Memory
transmission
0
2
Proxy reception
1: Yes
0: No
Yes
1
3
Inhibited to use
0
4
Quick online send
1: Yes
0: No
Yes
1
5
Remote select function
1: Yes
0: No
Yes
1
Refer to User program
“REMOTE
RECEPTION
SELECT”.
“REMOTE
RECEPTION
SELECT”.
6
Number of times of
CNG detection
CNG detection
Binary input
3 times
0 When a value outside
the set range is set,
the initial value is set.
the initial value is set.
7
Bit No.
Set range
Set range
6
7
8
1 to 4 times
1
8
1
S
W
9
1
Print of total
communication time
and total pages
communication time
and total pages
1: Yes
0: No
Yes
1
2
Inhibited to use
0
3
Ringing volume pattern
number
number
Binary input
1
0 When a value outside
the set range is set,
the initial value is set.
the initial value is set.
4
Bit No.
Set range
Set range
3
4
5
6
7
8
Pattern No. 1 to 35
0
5
0
6
0
7
0
8
1
SW
NO.
Data
No.
Item
Switch selection and contents of functions
Initial value
Remark
Click on the first or last page to see other AL-1566 (serv.man17) service manuals if exist.