PN-ZB01 (serv.man2) - Sharp Monitor Service Manual (repair manual). Page 119

Read Sharp PN-ZB01 (serv.man2) Service Manual online

CHAPTER 7. PN-E601/E521 DISASSEMBLY AND ASSEMBLY
PN-E601 PN-E601/E521 DISASSEMBLY AND ASSEMBLY
 7 – 11
9. KEY PWB
1 ) Remove 12pcs of Screw hiddlen sheet. Unscrew 8pcs of Screw (M4 x 6 Flat (Black)), and remove the front bezel LR. Unscrew 4pcs of Screw
(M4 x 6 Flat (Black)), and remove the front bezel D Assy.
CAUTION
NOTE FOR ASSEMBLY
n
When attaching the Front Bezel LR, engage the locating points in the holes of Front Bezel D/U.
n
Fit the screws to the holes on the panel side.
n
After tightening the screws, affix the screw hidden sheet properly without any displacement.
SCREW TIGHTENING TORQUE
n
0.9 - 1.1N •m
2 ) Remove the Key PWB fixing plate.  Lift up the Key PWB, and then disconnect the flat cable.
CAUTION
NOTE FOR ASSEMBLY
n
Place the Key PWB properly so that it is fitted to the recess of IR Filter.
n
When attaching the Key PWB fixing plate, slide and engage it to the rib.
n
Lightly pull the flat cable to confirm that it won't be disconnected.
Screw x 12
Panel side
Screw 
hidden sheet
Locating 
points
Locating 
points
Rib
Rib
Key PWB
Key PWB fixing plate
IR Filter
Page of 127
Display

Click on the first or last page to see other PN-ZB01 (serv.man2) service manuals if exist.