PN-ZB01 (serv.man2) - Sharp Monitor Service Manual (repair manual). Page 114

Read Sharp PN-ZB01 (serv.man2) Service Manual online

CHAPTER 7. PN-E601/E521 DISASSEMBLY AND ASSEMBLY
PN-E601 PN-E601/E521 DISASSEMBLY AND ASSEMBLY
 7 – 6
4. SHIELD PLATE ASSY
1 ) Unscrew 4pcs of ScrewC (M3 x 8s/sw (Silver)),and remove the Heat sinkD. Unscrew 10pcs of Screw A (M3 x 6 (Silver)) , 14pcs of Screw B
(M4 x 6 (Silver)), 2pcs of Screw E (M3 x 8s/sw (Silver)), and remove the Shield Plate Assy.
CAUTION
NOTE FOR ASSEMBLY
n
Be careful not to get the harness wire caught.
n
Make sure the locating points of Shield Plate (both sides) are engaged.
n
Tighten the screw A in the sequence of 
1, 2, 3,and 4.
SCREW TIGHTENING TORQUE
n
Screw A, Screw C : 0.7 - 0.9N •m
n
Screw B: 0.9 - 1.1N •m
A
Screw
x 10
E
Screw
x 2
B
Screw
x 14
Locating 
points
Locating 
points
2
1
3
D
4
Bottom 
side
Page of 127