Read Sharp PN-ZB01 (serv.man2) Service Manual online
CHAPTER 7. PN-E601/E521 DISASSEMBLY AND ASSEMBLY
PN-E601 PN-E601/E521 DISASSEMBLY AND ASSEMBLY
7 – 9
7. AC INLET CABLE / AC SWITCH
1 ) Unscrew Screw A (M3 x 6(Silver)), Screw B (M4 x 6 (Silver)) and Screw C (M4 x 8s/sw (Silver)), and remove AC Inlet Assy.
CAUTION
NOTE FOR ASSEMBLY
n
Make sure to attach the ground terminal with the swaged part up.
SCREW TIGHTENING TORQUE
n
Screw A: 0.7 - 0.9N •m
n
Screw B, Screw C: 0.9 - 1.1N •m
2 ) Disconnect 4 connectors, and remove the AC Switch. Unscrew 2pcs of Screws, and remove the AC Inlet Cable.
CAUTION
NOTE FOR ASSEMBLY
n
Beware of the connector color of AC Switch (Left: blue, Right: white) and the wire color (Upper: black, Lower: white).
n
Beware of the orientation of AC Inlet Cable. (Position of the terminals)
SCREW TIGHTENING TORQUE
n
0.5 - 0.7N •m
B
C
A
Black
White
White
Blue
Confirm that the circle
(o) is on the left side and
it is in the OFF state.
(o) is on the left side and
it is in the OFF state.
Screw x 2
AC Inlet Cable
AC Switch
Mark
When attaching, ensure
that the terminals are
oriented as indicated in the
engraved mark.
that the terminals are
oriented as indicated in the
engraved mark.
Click on the first or last page to see other PN-ZB01 (serv.man2) service manuals if exist.