UP-3300 (serv.man14). Service Manual - Sharp EPOS Service Manual (repair manual). Page 17

Read Sharp UP-3300 (serv.man14) Service Manual online

[Function] 
Enables or disables the panel switch.
Only the lowest bit of “n” is valid. 
When n=*******0, the panel switch is enabled.
When n=*******1, the panel switch is disabled. 
[Notes]
This command is valid for the online key and paper feed key.
[Default]
n = 0
No.
COMMAND
FUNCTION
CODE
32
ESC d n
Print and feed paper “n”
lines
<1Bh><63h>
<35h> n
[Range]
à
 n 
à
 255
[Function] 
Prints the data in the print buffer and feed the paper for “n” lines.
[Default] 
n = 0 
No.
COMMAND
FUNCTION
CODE
33
ESC i
Full cut
<1Bh><69h>
[Function]
Executes a full cut of the paper.
[Notes]
Valid only at the beginning of a line
Caution:
After this command is executed, 
You had better execute one line
feed or one line print to prevent
the Paper Jam.
No.
COMMAND
FUNCTION
CODE
34
ESC m
Partial cut
<1Bh><6Dh>
[Function]
Executes a partial cut of the paper.
[Notes]
Valid only at the beginning of a line
Caution:
After this command is executed,
You had better execute one line
feed or one line print to prevent
the Paper Jam.
No.
COMMAND
FUNCTION
CODE
35
ESC o
Print stamp
<1Bh><6Fh>
[Function]
Stamp printing of MAX 30 mm in vertical size is performed.
UP-T80BP has 2 stamp data area, and can set or print each of them.
In this command, print stamp No. 0.
This command acts same as following command;
GS o <00h>
[Notes]
Valid only at the beginning of a line.
6-dot feed is performed regardless of the line feed pitch setting before
the stamp data is printed.
[Reference]
ESC 4 n:
Set logo stamp
ESC 6 m n: Set logo stamp (select stamp No.)
GS o m:
Print logo stamp (select stamp No.)
[Reference]
A distance of 14.5 mm is provided between the cutter position and
thermal head position. In printing the stamp between them, vertical
size of 13.5 mm can be used.
The following methods are used to print the stamp data between the
cut position and print position.
1) Execution of print stamp command (ESC o)
2) Execution of cut command (ESC I)
Stamp printing in this case is for the next receipt. 
No.
COMMAND
FUNCTION
CODE
36
GS o m
Print stamp
<1Dh><6Fh> m
[Range]
à
 m 
à
 1: Printing stamp No.
[Function]
Stamp printing of MAX 30 mm in vertical size is performed.
UP-T80BP has 2 stamp data area, and can set or print each of them.
Select stamp No. by "m".
[Note]
Valid only at the beginning of a line.
6-dot feed is performed regardless of the line feed pitch setting before
the stamp data is printed.
[Reference]
ESC 4 n:
Set logo stamp
ESC 6 m n: Set logo stamp (select stamp No.)
ESC o:
Print logo stamp
[Reference]
A distance of 14.5 mm is provided between the cutter position and
thermal head position. In printing the stamp between them, vertical
size of 13.5 mm can be used.
The following methods are used to print the stamp data between the
cut position and print position.
1) Execution of print stamp command (ESC o)
2) Execution of cut command (GS V 1)
Stamp printing in this case of for the next receipt.
No.
COMMAND
FUNCTION
CODE
37
ESC q n
Set power failure mark
<1Bh><71h>n
14.5mm
13.5mm
Cutter position
Print position
(Thermal head
position)
Stamp
14.5mm
13.5mm
Cutter position
Print position
(Thermal head
position)
Stamp