UP-3300 (serv.man14). Service Manual - Sharp EPOS Service Manual (repair manual). Page 19

Read Sharp UP-3300 (serv.man14) Service Manual online

[Function] 
Defines the image data with the number of dots specified by n1 and
n2.
The number of dots in the horizontal direction is n1
×
8, and in the
vertical direction is n2 
×
 8.
“data” specifies the bit image data.
Black printing is 1; white printing is 0.
[Notes]
The set user-defined character data is not cleared until the
MASTER RESET and ESC @ commands are received.
If the above-mentioned data is out of the range, the setting is
disabled.
Image data memory structure
 
No.
COMMAND
FUNCTION
CODE
43
GS / n
Print image data
<1Dh><2Fh> n
[Range]
à
 n 
à
 3, 48 
à
 n  
à
 51
[Function] 
Prints the image data using the print mode specified by “m”. The dot
density selected by “m” is shown below.
m
Print mode
0, 48
Normal mode
1, 49
Double-width mode
2, 50
Double-height mode
3, 51
Quadruple mode
[Notes]
Image data printing is ignored while printing is performed. 
If the image data exceeds one line, the excess data is not printed.
6-dot feed is performed regardless of the line feed pitch setting before
the stamp data is printed.
[Reference]
[GS] *: Set image data 
No.
COMMAND
FUNCTION
CODE
44
GS:
Set starting/ending
position of macro definition
<1Dh><3Ah>
[Function]
Specifies the starting or ending position of the macro definition. 
If this command is received while defining the macro, it ends the
definition.
[Notes]
The macro range can be set up to 2048 bytes. 
Even if ESC @ is executed, the macro definition is not cleared. 
Normal printing operation is possible while defining the macro.
[Reference]
[GS] ^: Execute macro 
No.
COMMAND
FUNCTION
CODE
45
GS ^ r t m
Execute macro
<1Dh><5Eh> ...
[Function]
Executes the macro definition. 
r: Specifies the number of times to execute the macro. 
t:
Specifies the waiting time for executing the macro. 
Waiting time of t
×
100 msec is required for one execution:
Specifies the macro executing mode. 
m = 0 Continuous macro execution.
Executes “r” times continuously at the interval specified by
“t”. 
m = 1 Executes the macro by pressing the paper feed key.
After waiting the period specified by “t”, the ERROR LED
blinks and the printer waits for the receipt paper feed key
to be pressed. After the paper feed key is pressed, the
printer executes the macro once. The printer repeats this
operation “r” times.
[Notes]
If this command is received while defining the macro, the macro
definition is aborted. 
If the macro is not defined or if “r” is 0, nothing is executed. 
Paper cannot be fed with the receipt paper feed key while executing
the macro when “m” is 1. 
[Reference]
[GS]: Set starting/ending position of macro definition 
No.
COMMAND
FUNCTION
CODE
46
GS E n
Select print dendity
<1Dh><45h> n
[Range]
à
 n 
à
 99
[Function] 
Selects the print density. 
n = 00: 70% of standard density
n = 62: Standard density
n = 99: 118 % of standard density
n1x8-dots
n2
x8
d1
dn2
+1
d(n2)x2+1
d2
dn2
+2
dn2
d(n)x2
2
dn2 xn1 x8
MSB
LSB
Bit image
4 – 12
Page of 74