AU-X095 - Sharp Air Conditioner Service Manual (repair manual). Page 25

Read Sharp AU-X095 Service Manual online

25
AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E
LED Circuit
The LED is lit by setting CPU IC1 pin 63 to LOW output. It is inverted during serial signal reception, and flashes when
an error occurs.
Test Mode Circuit
The CPU< operation mode can be divided into the four types shown in the table below. Each mode can be selected by
connecting (a) and (b) in the diagram above to GND.
CPU (IC1) pin 58
R35
R36
R33
5V
R34
CPU (IC1) pin 59
a
b
Electrical burn-in mode
Individual board check mode
Air conditioner 40 Hz fixed mode
Normal operation mode
Yes
Yes
No
No
Yes
No
Yes
No
0 V
0 V
5 V
5 V
0 V
5 V
0 V
5 V
GND connection
CPU input
Operation Mode
a
b
58
59
CPU (IC1) pin 63
R31
LED
5V