AU-X095 - Sharp Air Conditioner Service Manual (repair manual). Page 27

Read Sharp AU-X095 Service Manual online

27
AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E
A/D conversion reference voltage (5V)
Compressor thermistor voltage
Heat exchanger pipe thermistor voltage
AC current induction voltage
Model switch
A/D converter circuit GND
CPU reset
Clock
Clock
IPM abnormal input
IPM abnormal input
Serial in
Serial out
Serial out
Outdoor fan control
Outdoor main relay control
4-way valve switch relay control
4-way valve power supply relay control
CPU GND
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
VRF
P5.7
P5.6
P5.5
P5.4
P5.3
P5.2
P5.1
P5.0
AGND
RESET
CK1
CK2
TEST1
STP
P4.6
P4.5
P4.4
P4.3
P4.2
P4.1
P4.0
P3.7
P3.6
P3.5
P3.4
P3.3
P3.2
P3.1
P3.0
Ø
GND
TEST2
Input
Input
Input
Input
Input
Input
Input
Input
Input
Input
Input
Input
Output
Output
Output
Output
Output
Output
Input
Pin
No.
Terminal
name
Input/
Output
Function
CPU Terminal Allocation
Page of 32
Display

Click on the first or last page to see other AU-X095 service manuals if exist.