AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E
Current Surge Suppression Circuit
When 220/240 V AC is supplied to terminal boards (1) and (N), an AC power supply rush current will flow temporarily
because there is an uncharged electrolytic capacitor on the load side. A current surge suppression circuit is included to
prevent damage to the circuit from this rush current,
When 220/240 V AC is supplied between terminal boards (1) and (N), the AC current passes through posistor PTC1 to
charge the electrolytic capacitor on the load side. The rush current is suppressed by passing it through the posistor.
When the load is charged on the electrolytic capacitor, CPU IC1 begins operation, and after an approximately 0.5
second delay, pin 23 goes to HIGH output. When pin 23 goes HIGH, digital transistor Q1 goes ON, MRY1 (main relay)
goes ON, and the circuit begins to operate normally.
Digital transistor Q1 is used here because, like the outdoor fan relay, the CPU cannot directly drive the relay.
CPU (IC1) pin 23
Noise
filter
circuit
13V
N
1
Terminal
Block
Load
Q1
MRY1
PTC1
D3