IPM and Power Supply Circuit
The IPM takes a 380 V DC input and generates a 13 V U-phase, V-phase, W-phase and XYZ-phase power supply from
its internal power supply circuit. GND is at CN2 pin 7 and 13 V is output at pin 9.
The 13 V power supply output from IPM is lowered by R15, giving an input voltage of 8 to 9 V to the three-terminal
regulator IC2, and generating the 5 V power supply for the control circuit.
IPM and IPM Fault Detection Circuit
The 5V power supply generated by the control circuit is input to IPM. Inside IPM it is used as the OPIC input power
supply and the fault output power supply. When IPM is operating correctly, the output from pin 10 on CN(2) is HIGH,
turning digital transistor Q5 to ON, and setting CPU input pins 15 and 16 to LOW input.
When IPM detects a fault in the current from the 380 V DC line, or detects an abnormal temperature, CN(2) pin 10 is set
to LOW output, turning Q5 to OFF, and setting CPU pins 15 and 16 to HIGH input. When CPU pin 15 goes to HIGH
input, the internal hardware sets all PWM waveform output (34 to 39) to OFF, and the LOW to HIGH rising edge causes
a software interrupt, causing fault processing to begin. CPU pin 16 is input to monitor the HIGH/LOW input level.
DC 380V
CN2
PM1 (IPM)
13V
IC2
5V
7805
C32
R15
DC 380V
5V
CN2
PM1 (IPM)
5V
C40
Q5
C32
R15
CPU (IC1) pin 15
CPU (IC1) pin 16