AU-X095 - Sharp Air Conditioner Service Manual (repair manual). Page 24

Read Sharp AU-X095 Service Manual online

24
AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E
IPM and Active Filter
The diagrams below show the current waveforms for an AC power source with and without the active filter.
As shown in the diagram, when there is no active filter, the current waveform is warped, causing harmonics. Inserting
an active filter reduces the warping and suppresses the harmonics.
The active filter is driven only when the compressor is in operation. This is controlled by CPU IC1 pin 48. When pin 48
is set to HIGH, transistor Q5 goes ON, and connector CN2 pin 12 on IPM goes LOW. When CN2 pin 12 goes LOW, the
IPM internal circuit causes 13 V to be generated at connector CN1 pin 1 on IPM, driving the active filter.
When the active filter detects an abnormal voltage, current or temperature, it sets connector CN1 pin 2 on the active
filter to HIGH. This causes the photo coupler in IPM to go OFF, putting connector CN2 pin 11 on IPM in OPEN state.
When CN2 pin 11 becomes OPEN, HIGH is input to CPU IC1 pin 49, starting the error processing. When error
processing begins, the compressor and the active filter are stopped.
The active filter is combined with a full-wave rectification circuit and smoothing circuit to generate a stable 380 V DC
voltage.
AC 220/
240V
CN1
CN1
Full
rectifier
circuit
Smoothing
circuit
Q5
5V
R27
CPU (IC1) pin 48
CPU (IC1) pin 49
CN2
Without active filter
With active filter
Page of 32