AU-X095 - Sharp Air Conditioner Service Manual (repair manual). Page 26

Read Sharp AU-X095 Service Manual online

26
AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E
INVERTER CIRCUIT
(1)  Noise filter circuit (AC)
This filter absorbs the conduction noise and radiation noise transmitted to the power supply by the switching of the
IPM internal IGBT or DC-DC converter.
(2) Surge absorption circuit
This is a protective circuit to eliminate erroneous operation or damage to the air conditioner due to a surge of
lightning.
WPE1 is a protective fuse against the current flowing from the 220/240 V AC power source.
(3) Full-rectifier circuit
The 220/240 V AC undergoes full-rectification under diode bridge DB1.
(4) Smoothing capacitor (C1)
This is a capacitor to smooth the voltage rectified by the diode bridge.
(5)  Fuse (WPE2)
A protective fuse on the main circuit in case the IPM or capacitor C3 breaks down. It is a 10 A fuse. If this fuse is
blown, the IPM and capacitor C3 are damaged. Check the control PCB carefully before replacing the fuse.
(6)  Noise filter circuit (DC)
Capacitor C2 and C3 are for reducing the noise generated by the switching of the 380 V DC voltage.
(7) Discharge resistor (R1)
This resistor is for discharging the charge on electrolytic capacitor C1 when the load side of the 380 V DC voltage
becomes in OPEN state.
(8)  Varistor (NR2) and fuse (WPE3)
The varistor protects the control circuit from a large surge such as lightning. When the surge is large, the varistor is
shorted, and the fuse blows. The varistor will also e broken. When this happens there will be a large crackling noise.
Replace the varistor and fuse.
SA1
WPE1
NR1
1
Terminal
Block
AC 220/240V
C7
C8
C5
C6
R2
L3
L2
AC 220/240V
DB1
Page of 32
Display