Read Panasonic WV-CS950 / WV-CS954E Service Manual online
2-7
REMOTE
OPERATE
PROG
ALARM
RESET
RESET
NORMAL
SYSTEM
ALARM OFF
EVR
Left
Switch
Right
Switch
Mode Selection
Switch
Program
Switch
Up
Switch
Down
Switch
Set
Switch
IN
OUT
STD. CAMERA
VP CAMERA
VIDEO
CAMERA
DC12V IN
RS232C
VP/STD Camera Selection Switch
RS232C Connector
3.2. Setting Up for Remote E.V.R.
Adjustment Kit
(1) Remote E.V.R. Adjustment Kit
Fig. 3-2-1
3. Connection and Setting Up for
Adjustment
3.1. Connection
8
The Fig. 3-1-1 shows the connecting diagram for the
Adjustment Procedure.
Adjustment Procedure.
Fig. 3-1-1
Test Chart
Floppy
Disk
Disk
Underscanned
Colour
Video Monitor
Colour
Video Monitor
Remote E.V.R.
Adjustment
Kit
Standard
Straight
RS-232C
Cable
Straight
RS-232C
Cable
RS232C
DC12V
IN
IN
Personal
Computer
Computer
75
Ω
WV-CS950
WV-CS954E
WV-CS954E
Vectorscope
CAMERA
IN
VIDEO
OUT
12 V DC
Power Supply Unit
Power Supply Unit
(For WV-CS954E)
220-240 V AC
(For WV-CS950)
220-240 V AC
(For WV-CS950)
12 V DC
Power Supply Unit
Power Supply Unit
8
Connect the Underscanned Colour Video Monitor to the
VIDEO OUT Connector of the Remote E.V.R. Adjustment
Kit through the Vectorscope by using the coaxial cables.
VIDEO OUT Connector of the Remote E.V.R. Adjustment
Kit through the Vectorscope by using the coaxial cables.
8
Connect the Video Output Connector of the WV-
CS950/WV-CS954E to the CAMERA IN Connector of the
Remote E.V.R. Adjustment Kit by using the coaxial cable.
CS950/WV-CS954E to the CAMERA IN Connector of the
Remote E.V.R. Adjustment Kit by using the coaxial cable.
8
Terminate the input terminal of the Underscanned Colour
Video monitor with 75
Video monitor with 75
Ω
.
8
Connect the 12 V DC Power Supply Unit to the Power
Cable of the WV-CS950 or the Power Connector of the
WV-CS954E.
Cable of the WV-CS950 or the Power Connector of the
WV-CS954E.
8
Connect the 12 V DC Power Supply Unit to the E.V.R.
Adjustment Kit.
Adjustment Kit.
8
Connect the Remote E.V.R. Adjustment Kit to the
Personel Computer (IBM PC/AT type) by using the
Standard Straight RS-232C cable.
Personel Computer (IBM PC/AT type) by using the
Standard Straight RS-232C cable.
8
Connect the probe of the Oscilloscope or Frequency
Counter at the desired Test Point in each adjustment
step.
Counter at the desired Test Point in each adjustment
step.
(2) Switch Setting
8
Referring to Fig. 3-2-2, remove four screws that secure
the Upper Cover and remove the Upper Cover.
the Upper Cover and remove the Upper Cover.
Remove four screws.
Upper Cover
Fig. 3-2-2