WV-CP480, WV-CP484E - Panasonic Video Monitoring Service Manual (repair manual). Page 10

Read Panasonic WV-CP480 / WV-CP484E Service Manual online

2-5
REMOTE
OPERATE
PROG
ALARM
RESET
NORMAL
SYSTEM
ALARM OFF
EVR
Left
Switch
Right
Switch
Mode Selection
Switch
Program
Switch
Up
Switch
Down
Switch
Set
Switch
IN
OUT
STD. CAMERA
VP CAMERA
VIDEO
CAMERA
DC12V IN
RS232C
VP/STD Camera Selection Switch
RS232C Connector
4.2. Setting Up for Remote E.V.R. 
Adjustment Kit
(1) Remote E.V.R. Adjustment Kit
Fig. 4-2-1
(2) Switch Setting  
8
Remove the Upper Cover.
8
Set the switch SW3 on the Board to the position as
shown in Fig. 4-2-2.
Fig. 4-2-2
8
Set the VP/STD.Camera Selection Switch on the Rear
Panel to STD CAMERA position. 
<Rear>
<F
ront>
Board
SW3
ON
<SW3>
<SW3>
1 2 3 4
Select switch #2 to ON (PAL) position.
#
ON
OFF
1
FIX
2
NTSC
PAL
3
FIX
4
FIX
(3) Menu Setting
8
Set the Mode Selection Switch on the Front Panel to the
"ALARM OFF" (center) position.
8
Keep pressing the Program Switch for 3 seconds or more
until "Program Menu" is displayed on the monitor screen.
8
Move the cursor to the "Controller Set Up" position by
pressing the Up and Down Switch.
8
Display the "Controller Set Up Menu" on the monitor by
pressing the Set Switch.
8
Move the cursor to the "Set Up Disable" position by press-
ing the Up and Down Switch.
8
Change "Disable" to "Enable" by pressing the Set Switch.
8
After completing the above setting, move the cursor to the
Communication position by pressing the Up and Down
Switch.
8
Display the "Communication Menu" on the monitor by
pressing the Set Switch .
8
After confirming the Baud Rate is 9600, finish this menu
by pressing the Program Switch twice.
(4) Installing E.V.R Adjustment Program
8
Make a copy of following necessory files to your computer
from original floppy disk.
RADJ2.EXE
CP480E.SEQ
CP48EABF.SEQ
CP480E.EV2
The Example given here is for A 2 drive computer, your
procedure might vary slightly depending on the drive con-
figuration.
8
Confirm that the contents of CONFIG.SYS file on your
computer is DEVICE=ANSI.SYS (Basic).
8
Insert floppy disk containing the E.V.R. Adjustment
Program into your floppy drive (for example,drive:A) and
type A:
8
At the prompt, type CD IBMPC and press ENTER key.
8
Type COPY RADJ2.EXE B: and press ENTER key.
8
Type CD\ and press ENTER key.
8
Type CD SEQ and press ENTER key.
8
Type COPY CP480E.SEQ B: and press ENTER key.
8
Type COPY CP48EABF.SEQ B: and press ENTER key.
8
Type CD\ and press ENTER key.
8
Type CD EVR and press ENTER key.
8
Type COPY CP480E.EV2 B: and press ENTER key.
8
After completing installation of program, you are ready to
use the E.V.R. Adjustment Program.
4.3. Setting Up
8
An initial setting of the Switch on the Left side Panel of the
WV-CP480 or on the Rear Panel of the WV-CP484E as
follows:
Gen-Lock Termination Switch
(Hi-Z, G/L 75
) ....................................................G/L 75
8
The adjustments should be done with this initial setting,
unless otherwise specified.
8
The adjustments should be done after 10 minutes warm
up.
Page of 49
Display

Click on the first or last page to see other WV-CP480 / WV-CP484E service manuals if exist.