WV-CP480, WV-CP484E - Panasonic Video Monitoring Service Manual (repair manual). Page 6

Read Panasonic WV-CP480 / WV-CP484E Service Manual online

2-1
1. Test Equipment Required
The following Test Equipments are required for Adjust-
ment of the Colour CCTV Camera WV-CP480/WV-
CP484E.
8
Oscilloscope
8
Frequency Counter
8
Vectorscope
8
Underscanned Colour Video Monitor
8
24 V AC/12 V DC Power Supply Unit
8
Personal Computer (IBM PC/AT type or equivalent)
8
Standard Straight RS-232C Cable
8
ALC Lens (WV-LA9C3B or equivalent)
8
Lux Meter
8
Lighting (140 footcandles (1 400 lx), Colour Temperature
3 200°K)
8
Colour Temperature Conversion Filters
Recommended manufacturer and part numbers are
shown in Table 1-1.
Table 1-1
8
Radiation Chart
8
Logarithmic Gray Scale Chart 
(Part Number: YWV2310RB99)
8
Colour Chip Chart (Part Number: YWV2100RB98)
8
White Chart or White Paper
8
Remote  Electric Variable Resistor (E.V.R.) Adjustment Kit
as shown in Fig. 1-1. (Part Number: YWV0EA1174AN) 
Fig. 1-1
ADJUSTMENT PROCEDURE
Conversion
KENKO
KODAK
3 200°K 
→ 
5 100°K C12
80B
3 200°K 
→ 
6 500°K C4 and C12
80B and 80C
2. Disassembling Procedure for
Adjustment
8
Referring to Fig. 2-1, remove two screws that secure the
Camera Mounting Adapter and remove the Camera
Mounting Adapter from the Camera.
(WV-CP480)
8
Referring to Fig. 2-2, remove two screws that secure the
Bottom Cover and remove the Buttom Cover.
8
Referring to Fig. 2-3, remove two screws that secure the
Upper Cover and remove the Upper Cover.
Remove two screws.
Camera Mounting
Adapter
Camera Mounting
Adapter
Camera
Remove two
 screws.
Camera
Fig. 2-1
(WV-CP480)
(WV-CP484E)
Fig. 2-2
Bottom Cover
Remove two screws.
Fig. 2-3
Remove two screws.
Upper Cover
Page of 49
Display

Click on the first or last page to see other WV-CP480 / WV-CP484E service manuals if exist.