2-4
4. Connection and Setting Up for
Adjustment
4.1. Connection
8
The Fig. 4-1-1 shows the connecting diagram for the
Adjustment Procedure.
8
Connect the Underscanned Colour Video Monitor to the
VIDEO OUT Connector of the Remote E.V.R. Adjustment
Kit through the Vectorscope by using the coaxial cables.
8
Connect the Video Output Connector of the WV-
CP480/WV-CP484E to the CAMERA IN Connector of the
Remote E.V.R. Adjustment Kit by using coaxial cable.
8
Terminate the input terminal of the Underscanned Colour
Video monitor with 75 
.
8
Connect the 24 V AC or 12 V DC Power Supply Unit to
the Power Input Terminal of the WV-CP484E.
8
Connect the 12 V DC Power Supply Unit to the E.V.R.
Adjustment Kit.
8
Connect the Remote E.V.R. Adjustment Kit to the
Personel Computer (IBM PC/AT type) by using the
Standard Straight RS-232C cable.
8
Connect the probe of the Oscilloscope or Frequency
Counter at the desired Test point in each adjustment
step.
Fig. 4-1-1
Test Chart
Floppy 
Disk
Underscanned
Colour
Video Monitor
Remote E.V.R.
Adjustment
Kit
Standard
Straight
RS-232C
Cable
RS232C
DC12V
IN
Personal 
Computer
75 
WV-CP480
WV-CP484E
Vectorscope
(For WV-CP484E)
220 V - 240 V AC
(For WV-CP480)
CAMERA
IN
VIDEO
OUT
Video Output
Connector
AC Inlet (WV-CP480)
Power Input Terminal
(WV-CP484E)
24 V AC or 12 V DC
Power Supply Unit
12 V DC
Power Supply Unit
8
Referring to Fig. 3-3, remove two screws that secure the
CCD Ass'y (IC102) and remove the CCD Ass'y (IC102)
from the ABF Chassis Ass'y.
Fig. 3-3
ABF Chassis Ass’y
CCD Ass’y
(IC102)
ABF Motor Ass’y
Remove two screws.