WV-CP240EX - Panasonic Video Monitoring Service Manual Simplified (repair manual). Page 8

Read Panasonic WV-CP240EX Service Manual Simplified online

4
8
Press the SAVE(F5) key of the Computer, then the
Computer will ask you for the file name.
8
Type  xxxxxxxx.EVR. Give an appropriate file name for
xxxxxxxx within 8 letters, but do not use CP240EXE.
8
Press the ENTER key.
8
This saving procedure is recommended to keep the cur-
rent adjustment status of the Camera.
8
Press the LOAD(F1) key and type CP240EXE.EVR and
press the ENTER key for presetting adjustment of the
Camera.
8
Press the ENTER key to start adjustment.
PANASONIC REMOTE EVR ADJUSTMENT SYSTEM CCTV PRODUCT:240ex EEPROM:0
✽   ✽   ✽   ✽   ✽   ✽   ✽  ✽   ✽  ✽   ✽  ✽  ✽   ✽   ✽   ✽   ✽   ✽  ✽  ✽  ✽  ✽  ✽ 
MENU
✽   ✽   ✽   ✽   ✽   ✽   ✽   ✽   ✽   ✽    ✽   ✽   ✽   
Page (1/1)
✽   ✽   ✽  ✽   ✽  
PAL
1. FSC ADJUSTMENT
3. ALC LEVEL
4. AGC OFF GAIN
5.1. OB LEVEL
5.2. VIDEO OUT GAIN
5.3. OB CONFIRM
6.1. BURST LEVEL 
6.2. BURST LEVEL 
6.3. BURST LEVEL 
6.4. BURST LEVEL 
7.1. 3200K R GAIN
7.2. 3200K B GAIN
7.3. 3200K PHASE
7.5. COLOUR CENTER POINT ADJUSTMENT
8.1. ATW CONFIRM
8.2. HI LIGHT CHROMA CLIP
8.3. ATW R CH HIGH LIMIT
8.4. ATW B CH HIGH LIMIT
8.5. ATW LIMIT MSB
<CONTENTS>  CN2/Pin-No.2 [CCD] 14.18750 MHz + - 40 Hz
<INSTRUCTION> PLEASE CHOOSE MENU DATA BY ARROW-KEY
LOAD (F1)          QUIT (F3)             SAVE (F5)
Table 5-1
<Adjustment Procedure-2 >
(E.V.R. Adjustment) 
8
Insert new disk containing the E.V.R. Adjustment pro-
gram into IBM PC/AT and turn on the Power Switch of
IBM PC/AT.
8
When starting an adjustment, at the prompt, type
LADJ CP240EXE and press the ENTER key, an initial
menu will be displayed in Table 5-1.
300 mV 
±
 30 mV
1. FSC  Adjustment
Test Point:
Pin 2 of CN2 (14MHz)
Sensor Board
8
Set the Synchronization Mode Selector (on the Video
Board SW1) to INT Position.
8
Connect the Frequency Counter to Pin 2 of CN2.
8
Adjust data with the ARROW keys so that the Subcurrier
Frequency becomes 14.18750 MHz ± 40 Hz.
8
Press the ENTER key for next adjustment.
3. ALC Level Adjustment
Test Point:
Pin 1 of CN2 (CDS OUT)
Sensor Board
8
Keep the Colour Temperature at 3 200° K.
8
Aim the Camera at the Logarithmic Gray Scale Chart.
8
Connect the Osilloscope to the Pin 1 of CN2.
8
Adjust data with the ARROW keys so that the CDS OUT
signal level becomes 380 mV ± 30 mV as shown in Fig.
5-2.
Fig. 5-2
8
Press the ENTER key for next adjustment.
4. AGC OFF Gain Adjustment
Test Point:
Pin 3 of CN2 (AGC OUT)
Sensor Board
8
Keep the Colour Temperature at 3 200° K.
8
Aim the Camera at the Logarithmic Gray Scale Chart.
8
Connect the Osilloscope to the Pin 3 of CN2.
8
Adjust data with the ARROW keys so that the AGC OUT
signal level becomes 300 mV ± 30 mV as shown in Fig.
5-3.
380 mV 
±
 30 mV
Fig.  5-3
8
Press the ENTER key for next adjustment.