WV-CP240EX - Panasonic Video Monitoring Service Manual Simplified (repair manual). Page 5

Read Panasonic WV-CP240EX Service Manual Simplified online

1
ADJUSTMENT PROCEDURE
Fig. 2-3 
8
Referring to Fig. 2-3, remove two screws that secure the
Upper Cover and remove the Upper Cover.
1. Test Equipment Required
The following Test Equipments are required for Adjust-
ment of the Colour CCTV Cameras.
8
Oscilloscope
8
Digital Voltmeter
8
Frequency Counter
8
Vectorscope
8
Underscanned Colour Video Monitor
8
12 V DC/24 V AC Power Supply Unit
8
Personal Computer (IBM PC/AT type (windows 95) or
equivalent)
8
ALC Lens (WV-LA9C3 or equivalent)
8
Lux Meter
8
Lighting (140 footcandles (1 400 lx), Colour Temperature
3 200°K)
8
Colour Temperature Conversion Filters
Recommended manufacturer and part numbers are
shown in Table 1-1.
Table 1-1
8
Radiation Chart
8
Logarithmic Gray Scale Chart 
(Part Number: YWV2310RB99)
8
Colour Chip Chart (Part Number: YWV2100RB98)
8
White Chart or White Paper
8
Electric Variable Resistor (E.V.R.) Adjustment Kit as shown
in Fig. 1-1. (Part Number: YWV0JA0019AN)   
2. Disassembling Procedure for
Adjustment
8
Referring to Fig. 2-1, remove two screws that secure the
Mount Adapter and remove the Mount Adapter.
8
Referring to Fig. 2-2, remove three screws that secure
the Bottom Cover and remove the Bottom Cover.
Remove two screws
Mount Adapter
Fig. 2-1
Fig. 2-2
Remove three screws
Bottom
Cover
Upper Cover
Remove two screws
Fig. 1-1
E.V.R. Adjustment Kit 
Cable for E.V.R. 
Adjustment Kit
Conversion
KENKO
KODAK
3 200°K 
→ 
5 100°K C12
80B
3 200°K 
→ 
6 400°K C4 and C12
80B and 80C
Page of 14
Display

Click on the first or last page to see other WV-CP240EX service manuals if exist.