Read Panasonic WV-CP240EX Service Manual Simplified online
8
8.1. ATW Confirmation
(Don't Change Data)
8
Press the ENTER key for next adjustment.
8.2. High Light Chroma Clip Adjustment
Test Point:
CN5 (Video Output Connector)Video Board
8
Keep the Colour Temperature at 3 200° K.
8
Aim the Camera at the White Chart or White Paper.
8
Set the Gain Control of the Vectorscope to maximum.
8
Adjust data with the ARROW
keys so that the
Chrominance level becomes minimum for the first time as
shown in Fig. 5-10.
shown in Fig. 5-10.
Fig. 5-10
8
Press the ENTER key.
8
Select the item "8.5. ATW LIMIT MSB" with the ARROW
keys and press the ENTER key, then the initial page as
shown in Table 5-3 will be displayed.
keys and press the ENTER key, then the initial page as
shown in Table 5-3 will be displayed.
(Data are just example)
Table 5-3
8
At the prompt, type the 4A and press the ENTER key.
8
Press the ESC key and select the item "8.3. ATW R CH
HIGH LIMIT" with the ARROW keys.
HIGH LIMIT" with the ARROW keys.
8
Press the ENTER key for next adjustment.
8.3. ATW Rch High Limit Adjustment
Test Point:
CN5 (Video Output Connector) Video Board
8
Change the Colour Temperature from 3 200°K to 6 400°K
by mounting the Colour Temperature Conversion Filters
on the Lens.
by mounting the Colour Temperature Conversion Filters
on the Lens.
8
Aim the Camera at the White Chart or White Paper.
8
Set the Gain Control of the Vectorscope to maximum.
cy
g
M
G
Y
L
yl
B
b
G
C
Y
dG
10
°
0
°
10
°
dø
100%
75%
R
V
U
mg
r
20%
20%
dG
Minimize Chrominance
Level.
Level.
8
Adjust data with the ARROW keys so that the vector posi-
tions at shifts by 40 mV ± 20 mV to the Cyan side of the
Vectorscope as shown in Fig. 5-11.
tions at shifts by 40 mV ± 20 mV to the Cyan side of the
Vectorscope as shown in Fig. 5-11.
8
Press the ENTER key for next adjustment.
8.4. ATW Bch High Limit Adjustment
Test Point: CN5 (Video Output Connector)Video Board
8
Keep the Colour Temperature at 6 400°K.
8
Adjust data with the ARROW keys so that the vector posi-
tions at shifts by 40 mV ± 20 mV to the Cyan side of the
Vectorscope as shown in Fig. 5-10.
tions at shifts by 40 mV ± 20 mV to the Cyan side of the
Vectorscope as shown in Fig. 5-10.
8
In case of completing the adjustment for steps 8.3 and
8.4.
8.4.
8
After completing the adjustment, press the QUIT (F3) key,
then the menu as shown in "<SAVE CAMERA DATA TO
FILE :
then the menu as shown in "<SAVE CAMERA DATA TO
FILE :
∗∗∗∗∗∗
, EVR? Y/N>" will be displayed.
8
Press the N key, and then press the ENTER key to finish
this adjustment procedure.
this adjustment procedure.
8
In case of not completing the adjustment for steps 8.3 and
8.4.
8.4.
8
Press the ENTER key for next adjustment.
8.5. ATW Limit MSB Adjustment
Test Point: CN5 (Video Output Connector)Video Board
8
Keep the Colour Temperature at 6 400°K.
8
In case of not completing the adjustment for step 8.3.
8
At the prompt, type the 48 and press the ENTER key for
repeat adjustment step 8.3.
repeat adjustment step 8.3.
8
In case of not completing the adjustment for step 8.4.
8
Or at the prompt, type the 42 and press the ENTER key
for repeat adjustment step 8.4.
for repeat adjustment step 8.4.
8
In case of not completing the adjustment for steps 8.3 and
8.4 both.
8.4 both.
8
Or at the prompt, type the 40 and press the ENTER key
for repeat adjustment steps 8.3 and 8.4 both.
for repeat adjustment steps 8.3 and 8.4 both.
8
Repeat adjustment steps 8.3 to 8.5 until vector positions
at shifts by 40 mV ± 20 mV to the Cyan side of the
Vectorscope.
at shifts by 40 mV ± 20 mV to the Cyan side of the
Vectorscope.
8
After completing the adjustment, press the QUIT (F3) key,
then the menu as shown in "<SAVE CAMERA DATA TO
FILE :
then the menu as shown in "<SAVE CAMERA DATA TO
FILE :
∗∗∗∗∗∗
, EVR? Y/N>" will be displayed.
8
Press the N key, and then press the ENTER key to finish
this adjustment procedure.
this adjustment procedure.
PANASONIC REMOTE EVR ADJUSTMENT SYSTEM CCTV PRODUCT:240ex EEPROM:0
✽ ✽ ✽ ✽ ✽ ✽ ✽ ✽ ✽ ✽ ✽ ✽ ✽ ✽ ✽ ✽ ✽ ✽ ✽ ✽ ✽ ✽ ✽
MENU
✽ ✽ ✽ ✽ ✽ ✽ ✽ ✽ ✽ ✽ ✽ ✽ ✽
Page (1/1)
✽ ✽ ✽ ✽
PAL
8.5. ATW LIMIT MSB
SET LIMIT MSB 48h or 42h or 40h or 4ah
<DEVICE> RAM0
<ADDRESS> 088
<DATA> 42-__
<MEASURE>
<INSTRUCTION> PLEASE ADJUST DATA BY ARROW-KEY
<ADDRESS> 088
<DATA> 42-__
<MEASURE>
<INSTRUCTION> PLEASE ADJUST DATA BY ARROW-KEY
LOAD (F1) QUIT (F3) SAVE (F5)
Fig. 5-11
cy
g
M
G
Y
L
yl
B
b
G
C
Y
dG
10
°
0
°
10
°
dø
100%
75%
R
V
U
mg
r
20%
20%
dG
Shifts
40 mV
40 mV
±
20mV