WV-CP160 - Panasonic Video Monitoring Service Manual (repair manual). Page 4

Read Panasonic WV-CP160 Service Manual online

ADJUSTMENT PROCEDURE
1. Test Equipment Required
The following test equipment are required for adjustment
of  the Colour CCTV Camera WV-CP160.
Oscilloscope
Frequency Counter
Waveform Monitor
Vectorscope
Underscanned Colour Video Monitor
Camera Drive Unit (WV-PS11B or WV-PS104C)
12 V DC Power Supply Unit
Personal Computer (IBM PC/AT type or equivalent)
Standard Straight RS-232C Cable
ALC Lens (WV-LA9C3A, WV-LA9C3B or equivalent)
Lux Meter
Lighting (275 footcandles (2,750 ± 150 lux), Colour
Temperature 5,100 ± 100 K)
Colour Temperature Conversion Filters
(KENKO: W12, C4 or equivalent)
Radiation Chart
Logarithmic Gray Scale Chart. 
(Part Number:YWV2310RB99) 
Extension Cable as shown in Fig. 1-1.
(Part Number: YWV0EA1171AN) 
Make a conversion cable as follows.
Fig. 1-2
Remote Electric Variable Resistor (E. V. R.) kit as shown in
Fig. 1-2. (Part Number: YWV0EA1174AN) 
Fig. 1-3
13
12
11
10
9
8
7
6
5
4
3
2
1
26
25
24
23
22
21
20
19
18
17
16
15
14
GND
T (B)
R (B)
To
E. V. R.
Kit
To PC
Via RS-232C
Cable
2. Disassembling Procedure for
Adjustment
Referring to Fig. 2-1, remove two screws that secure the
Mount Adaptor and remove the Mount Adaptor.
Referring to Fig. 2-2, remove two screws that secure the
Main Cover and remove the Main Cover.
Remove one screw that secure the Rear Cover and
remove the Rear Cover.
Remove two screws
Mount Adaptor
Fig. 2-1
Fig. 2-2
Remove two screws
Main Cover
– 2 –
WV-CP160
Fig. 1-1
To 
Main Board 
CN404
To 
VP Board 
CN1
CN3
CN2
Remove
one screw
Rear Cover
Page of 26
Display

Click on the first or last page to see other WV-CP160 service manuals if exist.