WV-CP160 - Panasonic Video Monitoring Service Manual (repair manual). Page 12

Read Panasonic WV-CP160 Service Manual online

– 10 –
WV-CP160
10.1. 5100K R Gain Adjustment
Menu:
10.1. 5100K R_GAIN
Test Point:
CN2 (Video Output Terminal)
VP Board
Aim the Camera at the Colour Chip Chart.
Change the Colour Temperature from the 3200K to
5100K by removing the Colour Conversion Filter from the
Lens.
Adjust data with the ARROW keys so that the Red gain
becomes 220 ± 5%.
Press the ENTER key for next adjustment.
10.2. 5100K B Gain Adjustment
Menu:
10.2. 5100K B_GAIN
Test Point:
CN2 (Video Output Terminal)
VP Board
Keep the Colour Temperature at 5100K.
Adjust data with the ARROW keys so that the Yellow gain
becomes 120 ± 5 %.
Repeat adjusment steps 10.1 and 10.2 until both chromi-
nance phase and gain are adjusted to proper position as
shown in Fig. 5-13 and Table 5-4.
cy
g
M
G
Y
L
yl
B
b
G
C
Y
dG
10
°
0
°
10
°
100%
75%
R
V
U
mg
r
20%
20%
dG
Fig. 5-13
Table 5-4
Press the ENTER key for next adjustment.
Minimize
Chrominance
Level.
Fig. 5-14
After completing of the adjustment, press the QUIT (F3)
key, then the menu as shown in "<SAVE CAMERA DATA
TO FILE : 
✽ ✽ ✽  
, EVR? Y/N> will be displayed.
Press the key, and then press the ENTER key to finish
of this adjustment procedure.
11. High light Chroma Clip Adjustment
Menu:
11. HI LIGHT CHROMA CLIP
Test Point:
CN2 (Video Output Terminal)
VP Board
Adjust:
RAM8 (01F)
Aim the Camera at the White Chart or White Paper.
Return the Colour Temperature from the 5100K to 3200K
by mounting the Colour Conversion Filter W12 on the
Lens.
Adjust data with the ARROW keys so that the false
chrominance level becomes minimum as shown in Fig. 5-
14.
Note: The Data of 01F should be adjusted from FF, the first 
minimum point of the false chrominance signal is as 
adjusting point.
Phase
Gain
Red
104 
±
 2
°
220 
±
 5 %
Yellow
165 
±
 5
°
120 
±
 5 %
Page of 26
Display

Click on the first or last page to see other WV-CP160 service manuals if exist.